GS/
LYNX
14P
2014-12-09
33
ADJUSTING THE V-BELT TENSION FOR THE ROTOR
While operating the machine the correct tension of the rotor V-belts is ensured by a gas spring, which
eliminates the clearance because of normal wear and elongation of the V-belts.
The V-belts are automatically kept tensioned as soon as the gear lever is moved down and the clutch is
connected.
Maintenance
Rotor disengaged
Rotor engaged
Gas spring
Check V-belt tension with pretension measuring device
Optikrik
1.
Ensure that the indicator hand is in rest position.
3.
With one finger press slowly onto the pressure surface
until the indicator hand releases.
4.
The intersection of indicator hand and scale must be at
200 Nm.
The pretension measuring device Optikrik
(available at your agent's)
is used for checking the V-belt tension
at the LYNX and any other machine.
In case of the LYNX the V-belts are to be tensioned with 200 Nm.
2.
Engage the V-belt and place the device flat
on the back of the V-belt in the middle of the
two pulleys.
Optikrik
Indicator hand
(released)
Rubber finger loop
Pressure surface
V-belt
Pressure spring
Содержание SAELEN GS/LYNX14P
Страница 1: ......
Страница 2: ......
Страница 7: ...GS LYNX14P 2014 12 09 7 ...
Страница 29: ...GS LYNX14P 2014 12 09 29 DIP STICK ENGINE OIL DIP STICK HYDRAULIC OIL OIL LEVELS Maintenance ...
Страница 41: ...GS LYNX14P 2014 12 09 41 Hydraulic connections ...
Страница 42: ...GS LYNX14P 2014 12 09 42 Hydraulic Circuit Diagram ...
Страница 43: ...GS LYNX14P 2014 12 09 43 Electric Circuit Diagram ...
Страница 44: ......