EXPULSION CHANNEL SAFEGUARD
The machine is fitted with a safeguard for expulsion channel:
This fuse consists of a proximity sensor installed on the lower yellow rotor housing. The electric switching
contact is established when the sensor is approaching the magnet at the chimney base. When the
expulsion chimney is opened, the contact is interrupted and the engine is switched off.
The proximity switch must not enter in
contact with the magnet. The distance
between sensor and magnet must amount to
6 mm +/-3 .