SYSTEM REQUIREMENTS
WATER HEATING (Gas or Electric)
Electric Water Heater
minimum 33-36kw; minimum 10 gpm flow
rate; distilled water with 10% glycol
(suggested); 1" plumbing
Gas Water Heater
300 BTU; minimum 10 gpm flow rate; distilled
water with 10% glycol (suggested); 1"
plumbing
COOLING
minimum 10 tons of cooling; 1" plumbing
VACUUM
suggested:
6.1 cfm / 174 L/min
SECTION III: STARTUP PROCEDURES
In order to operate the AutoVap30 at correct capacity, the system requires the ancillary
equipment to be turned on and set at the correct parameters.
Operators shall follow the following procedures and verify all equipment is functioning properly
before proceeding to the next steps of operation.
CHILLER STARTUP
Please refer to the user manual of your chiller system for guidance of operation.
The suggested operating temperature of your chiller system is
41-44°F (5-7°C)
WATER HEATER STARTUP
Please refer to the user manual of your water heater system for guidance of operation.
Note: Most AutoVap30 water heater systems have a manifold with a recirculating water pump.
Powering on this recirculating water pump will provide flow to the water heater and trigger the
water heater to heat the water.
Ideal Parameters:
Water Heater Setpoint: 185
-194°F (85-90°C)
Note
: This is an ideal setpoint if you are recovering ethanol. Other solvents may have a
lower temperature setpoint. (ie, hexane)
Note
: Gas water heaters tend to operate better at a setpoint no higher than 186°F (85.5°
C)
Recirculating Water Pump: The system should be able to maintain a flow rate of at least 10
gallons per minute.
Содержание AutoVap30
Страница 1: ...Copyright 2020 by TruSteel LLC All Rights Reserved TruSteel AutoVap30 User Manual Version 1 9 ...
Страница 3: ...TruSteel AutoVap30 User Manual v 1 9 3 39 STEP 8 SHUT DOWN 39 ...
Страница 5: ...TruSteel AutoVap30 User Manual v 1 9 5 39 ...
Страница 6: ...TruSteel AutoVap30 User Manual v 1 9 6 39 ...
Страница 7: ...TruSteel AutoVap30 User Manual v 1 9 7 39 ...
Страница 10: ...TruSteel AutoVap30 User Manual v 1 9 10 39 Pull the Red EMERGENCY button OUT Turn all H O A switches to AUTO ...
Страница 36: ...TruSteel AutoVap30 User Manual v 1 9 36 39 AV30 FLOW IMAGE CUTAWAY CLICK HERE FOR LARGER VIEW ...
Страница 37: ...TruSteel AutoVap30 User Manual v 1 9 37 39 ...