TruSteel AutoVap30 User Manual | | v. 1.9
29 / 39
Thermocouple temperature status for all TC
·
Current status of every thermocouple on the AutoVap
·
There is currently no temperature control only status, and temperature alarm indications if
temperature goes above or below setpoint value
·
Red: check temperature
·
Yelllow: temperature warning
·
Green: temperature in good condition
·
No Color: thermocouple is not operational, termperature value will default to lowest
temperature reading of 14 Degrees F
ALARMS
Enable/Disable Alarms and adjust alarm setpoints
ALARMS 1
·
Evap Inlet Temperature
: If Enabled an Alarm Indication will be initiated for this if the
temperature drops below the alarm setpoint for the preset amount of time. If the condition
clears before the Alarm can be reset than the Alarm indication will clear itself.
·
Evap Outlet Temperature
: If Enabled an Alarm Indication will be initiated for this if the
temperature drops below the alarm setpoint for the preset amount of time. If the condition
clears before the Alarm can be reset than the Alarm indication will clear itself.
·
Condenser Inlet Temperature
: If Enabled an Alarm Indication will be initiated for this if
the temperature rises above the alarm setpoint for the preset amount of time. If the
condition clears before the Alarm can be reset than the Alarm indication will clear itself.
·
Preheater Inlet Temperature
: If Enabled an Alarm Indication will be initiated for this if the
temperature drops below the alarm setpoint for the preset amount of time. If the condition
clears before the Alarm can be reset than the Alarm indication will clear itself.
·
Feed Inlet Temperature
: If Enabled an Alarm Indication will be initiated for this if the
temperature drops below the alarm setpoint for the preset amount of time. If the condition
Содержание AutoVap30
Страница 1: ...Copyright 2020 by TruSteel LLC All Rights Reserved TruSteel AutoVap30 User Manual Version 1 9 ...
Страница 3: ...TruSteel AutoVap30 User Manual v 1 9 3 39 STEP 8 SHUT DOWN 39 ...
Страница 5: ...TruSteel AutoVap30 User Manual v 1 9 5 39 ...
Страница 6: ...TruSteel AutoVap30 User Manual v 1 9 6 39 ...
Страница 7: ...TruSteel AutoVap30 User Manual v 1 9 7 39 ...
Страница 10: ...TruSteel AutoVap30 User Manual v 1 9 10 39 Pull the Red EMERGENCY button OUT Turn all H O A switches to AUTO ...
Страница 36: ...TruSteel AutoVap30 User Manual v 1 9 36 39 AV30 FLOW IMAGE CUTAWAY CLICK HERE FOR LARGER VIEW ...
Страница 37: ...TruSteel AutoVap30 User Manual v 1 9 37 39 ...