TruSteel AutoVap30 User Manual | | v. 1.9
9 / 39
Note
: If the flow rate has dropped to below 10 gpm, you may need to re-prime the water
heater system. (See AutoVap30 Pre-Installation Manual)
Pro Tip
CHECK WATER HEATER DIAGNOSTICS (Electric Heater Models Only)
This is an important step to check each day of operation to be sure the flow is high enough.
Press and Hold both the UP and DOWN arrows simultaneously for 1-2 seconds and release.
You should not be in diagnostic mode.
Numbers will begin
“flashing” on the water heater screen.
1st number is the heater temperature setpoint
2nd number is the temperature
“OUT” of the heater to the AutoVap
3rd number is the temperature
“IN”, back from the AutoVap
4th number is the
“Flow Rate” in gallons/minute
The Flow Rate is very important
You must have a flow rate above 10 gallons/minute.
If the flow rate is below that, the AutoVap may not operate efficiently.
The flow rate should be between 10-18 GPM for optimal operation.
If the flow rate is below 10 gallon per minute you must refill the heater with water. Do this when
the before the heater is turned on. You must refill the heating system while the system cold.
VACUUM PUMP STARTUP
Please refer to the user manual of your chiller system for guidance of operation.
#VERIFY VACUUM
You can verify the system is pulling vacuum from the AutoVap itself.
Open the vacuum valve on the vacuum manifold on the AutoVap. Open the vacuum fine tune
adjustment. There should be vacuum flow.
SECTION IV: OPERATING PROCEDURES
POWER ON SYSTEM
POWER ON THE AUTOVAP 30 SOLVENT RECOVERY SYSTEM
1. POWER ON PLC
Turn the Main Disconnect to the
“ON” position
Содержание AutoVap30
Страница 1: ...Copyright 2020 by TruSteel LLC All Rights Reserved TruSteel AutoVap30 User Manual Version 1 9 ...
Страница 3: ...TruSteel AutoVap30 User Manual v 1 9 3 39 STEP 8 SHUT DOWN 39 ...
Страница 5: ...TruSteel AutoVap30 User Manual v 1 9 5 39 ...
Страница 6: ...TruSteel AutoVap30 User Manual v 1 9 6 39 ...
Страница 7: ...TruSteel AutoVap30 User Manual v 1 9 7 39 ...
Страница 10: ...TruSteel AutoVap30 User Manual v 1 9 10 39 Pull the Red EMERGENCY button OUT Turn all H O A switches to AUTO ...
Страница 36: ...TruSteel AutoVap30 User Manual v 1 9 36 39 AV30 FLOW IMAGE CUTAWAY CLICK HERE FOR LARGER VIEW ...
Страница 37: ...TruSteel AutoVap30 User Manual v 1 9 37 39 ...