TruSteel AutoVap30 User Manual | | v. 1.9
14 / 39
3. Adjust vacuum pressure to 1.2-2.0 PSIA (pounds per square inch absolute)
The black needle valve located on the vacuum manifold is your fine adjust for vacuum
By turning the needle valve clockwise, you will be increasing vacuum on the system
By turning the needle valve counterclockwise, you will be releasing vacuum on the system
4. Verify Vacuum Pressure (1.2-2.0 PSIA)
Locate Vacuum Pressure on the HMI Home Screen and verify the
“VACUUM” is in range
(1.2-2.0 PSIA)
5. Open Feed Line Ball Valve
Locate your feed line ball valve and open it. The vacuum pressure will draw material from
the feed line, through the pump(priming it), and into the system.
Once there is liquid in the sight glass below the preheater, the AutoVap can be started.
Содержание AutoVap30
Страница 1: ...Copyright 2020 by TruSteel LLC All Rights Reserved TruSteel AutoVap30 User Manual Version 1 9 ...
Страница 3: ...TruSteel AutoVap30 User Manual v 1 9 3 39 STEP 8 SHUT DOWN 39 ...
Страница 5: ...TruSteel AutoVap30 User Manual v 1 9 5 39 ...
Страница 6: ...TruSteel AutoVap30 User Manual v 1 9 6 39 ...
Страница 7: ...TruSteel AutoVap30 User Manual v 1 9 7 39 ...
Страница 10: ...TruSteel AutoVap30 User Manual v 1 9 10 39 Pull the Red EMERGENCY button OUT Turn all H O A switches to AUTO ...
Страница 36: ...TruSteel AutoVap30 User Manual v 1 9 36 39 AV30 FLOW IMAGE CUTAWAY CLICK HERE FOR LARGER VIEW ...
Страница 37: ...TruSteel AutoVap30 User Manual v 1 9 37 39 ...