oil heater IDS 20 / IDS 30
Assembly of a flue pipe (optional)
When the flue pipe is mounted to the flue pipe connection for
the discharge of the exhaust gas, the device must only be
operated in outdoor areas. Please observe the following:
• The flue pipe must not exceed a length of 1 m.
• Bends and elbows in the flue pipe are prohibited.
• If the device is used out of doors, a rain cap must be
mounted to the end to prevent the penetration of rain
water and dirt.
• The flue pipe must be designed in a way to prevent
counter-pressure.
• To ensure failure-free operation the flue pipe must be
installed upward.
Chimney duct
The following schematic representation should be considered
when planning a chimney duct:
1
2
4
5
Wall duct
The following schematic representation should be considered
when planning a wall duct:
1
3
5
6
No. Designation
No. Designation
A
min. 1 m
1
flue pipe connection
B
min. 1 m
2
cleaning opening with
explosion protection flap
C
as short as possible 3
outer wall
D
≥ Ø 120 mm /
150 mm
4
chimney – inside
min. 20 x 20 cm
E
min. 1 m
5
wall duct with elbow min. 5°
6
draught booster H-shaped
Содержание IDS 20