oil heater IDS 20 / IDS 30
Malfunction
Meaning
Remedy
Fan does not start and flame does not ignite;
operating display is switched off
Controller set incorrectly
Check whether the controller is set correctly (e.g.
the temperature set at the thermostat must be
higher than the room temperature).
Controller faulty
Have the controller replaced by the customer
service.
Fan does not start or switches off during start-up/
operation; operating display flashes in orange
No power supply
Check the characteristics of the electrical system
(230 V, 1 ~, 50 Hz).
Check the functionality and position of the
selector switch.
Check the fuse for soundness.
Voltage < 175 V
Check the supply voltage. The device will restart
automatically when the voltage value
exceeds 175 V.
Voltage > 265 V
Check the supply voltage. The device will restart
automatically when the voltage value falls
below 250 V.
Fan switches off during start-up/operation;
operating display illuminated in red, self-
diagnosis indication flashes in orange
Flame present prior to ignition of the transformer Instruct the customer service to have the device
cleaned and to have fuel oil residues removed
from the combustion chamber.
Photo cell faulty
Have the photo cell exchanged by the customer
service.
Fan switches off during start-up/operation;
operating display permanently illuminated in red,
self-diagnosis indication flashes in red or red/
green
Motor winding interrupted or blown
Have the motor replaced by the customer service.
Motor bearing blocked
Have the motor bearing replaced by the customer
service.
Motor capacitor blown
Have the motor capacitor replaced by the
customer service.
No ignition
Check the connections of the ignition cables at
the electrodes and the transformer.
Check the position and the distance of the
electrodes.
Check whether the electrodes are clean.
Have the transformer replaced by the customer
service.
Flame monitoring system faulty
Have the flame monitoring system replaced by
the customer service.
Photo cell faulty
Have the photo cell cleaned or replaced by the
customer service.
Burner is supplied with no or insufficient fuel oil
Charge the customer service with the following
tasks:
•
to have the coupling between the pump
and the motor checked for soundness
•
to have the fuel oil circuit checked for
intruded air and to have the lines and filter
seal checked for tightness
•
to have the nozzle cleaned and replaced
Magnet valve faulty
Charge the customer service with the following
tasks:
•
to have the electrical connections checked.
•
to have the safety thermostat L1 checked.
•
to have the magnet valve cleaned or
replaced
Содержание IDS 20
Страница 1: ...TRT BA IDS20 IDS30 TC2019 43 003 EN IDS 20 IDS 30 EN ORIGINAL INSTRUCTIONS OIL HEATER ...
Страница 20: ...20 EN oil heater IDS 20 IDS 30 Wiring diagram IDS 20 IDS 30 ...
Страница 26: ...Trotec GmbH Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com ...