EN
7
oil heater IDS 20 / IDS 30
Mounting the transport handle
1. Connect the transport handle (3) to the rear of the device.
2. Make sure that the holes in the transport handle are
aligned with the holes in the frame (7).
3. Secure the transport handle to the frame using the screws
and nuts.
Assembly of the exhaust line
Warning
Note that this device must not be put into operation
unless there is an exhaust line mounted at the flue pipe
connection!
Assembly of a closed exhaust line
Warning
Make sure that in every operating and weather
condition a vacuum of > 0.1 mbar is created in the
exhaust line.
This vacuum guarantees a safe discharge of exhaust
gases from the room. The exhaust line must be
installed upward. There must be no bends or elbows in
the first 3 metres of the exhaust line!
If the device is used in closed rooms and the combustion gases
are discharged via a chimney, a fresh air supply of
approx. 80 m³/h (air inlet opening approx. 0.5 m²) must be
ensured.
• Prior to planning the flue gas system, gather information
about the national legislation and contact a responsible
specialist (cf. DIN 18160 in Germany).
• Ensure an unimpeded and sufficient combustion air supply
(e.g. by means of ventilation openings in doors, ceilings,
windows, walls or via interconnected airways).
• Have the exhaust emission of the burner checked at
regular intervals.
Содержание IDS 20
Страница 1: ...TRT BA IDS20 IDS30 TC2019 43 003 EN IDS 20 IDS 30 EN ORIGINAL INSTRUCTIONS OIL HEATER ...
Страница 20: ...20 EN oil heater IDS 20 IDS 30 Wiring diagram IDS 20 IDS 30 ...
Страница 26: ...Trotec GmbH Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com ...