User Manual ROQSTAR
Support: www.tronteq.de/support
Release 11/2016
Page 25 of 37
9.2.
SNMP Traps
SNMP Traps can be sent to a designated IP address in the event of an error. Only SNMP Traps v1
are supported.
Option
Description
IP address
host system
Trap Community
name of community for Trap message
Traps are generated in the following events:
-
Fall below minimum operating temperature
-
Overrun maximum operating temperature
-
Operating temperature is valid range after a fall below or overrun event of the operating
temperature
10. LLDP
Order No. 006-130-101/102
The LLDP service enables the detection of adjacent network devices. You can activate and configure
this service in the web interface at
Configuration > LLDP.
The left table is for setting, the right table indicates the neighbored devices. If an interface is set to
"enable" the ROQSTAR is processing incoming LLDP frames. In a 30-second interval it sends LLDP
frames that include the following information:
-
system name
-
system description
-
interface name
-
interface description
-
MAC address