User Manual ROQSTAR
Support: www.tronteq.de/support
Release 11/2016
Page 30 of 37
13.3. Log files
Order No. 006-130-101/102
The device is capable of holding occurring events in log files. This includes the system status,
messages and events induced by the user. Thereby 1000 events are logged.
The log files contain the information per events
► date (with time)
► priority
► source
► message
The user can select at
Monitoring > Logging
, which events should be monitored. The following events
are available:
Event
Importance
power
changes in the power supply
thermal
about / below the temperature limits
network
change at the WAN port
switch
change of the Switch Ports
system
events of the system
fault
change of the fault contact
user
login / logout in the web interface
DHCP
assigning of IP addresses
The log entries are listed in the web interface at
Monitoring > Logging
. Here is an example of the log
entries:
Time
Priority Type
Description
2015-10-02T15:11:15Z
INFO
switch
interface 10 down
2015-10-02T15:11:15Z
INFO
switch
interface 5 down
2015-10-02T15:11:15Z
INFO
switch
interface 4 down
2015-10-02T15:11:15Z
INFO
switch
interface 3 down
2015-10-02T15:11:15Z
INFO
switch
interface 2 down
2015-10-02T15:11:15Z
INFO
switch
interface 7 down
2015-10-02T15:11:15Z
INFO
switch
interface 9 down
2015-10-02T15:11:15Z
INFO
switch
interface 8 down
2015-10-02T15:11:15Z
INFO
switch
interface 6 down
2015-10-02T15:11:15Z
INFO
network
interface 1 up
2015-10-02T15:11:15Z
INFO
system
system startup