4.
First start-up
4.1.
Default Settings
Order No. 006-130-100
The device with the Order No. 006-130-100 are unmanaged Switches, therefore no configuration can
be made. After wiring the power supply connection the Switch transfers data on all Ethernet ports.
Order No. 006-130-101/102
The device is delivered pre-configured. The factory configuration is chosen so that after switching on
the device sends the data immediately to all Ethernet ports. The following settings are set at the
factory:
► Web interface IP address:
192.168.1.1
► Web interface user name:
admin
► Web interface password:
password
► Web interface access:
port 1-8
► Ethernet ports:
activated
► Auto-Negotiation
activated
► VLAN, QoS, port mirroring:
deactivated
► Link Aggregation:
deactivated
► SNMP
deactivated
► Fault Contact:
normally open
► Fault Contact events:
power; over temperature
The following configuration is only available in Order No. 006-130-102
► DHCP
activated
o
pool
192.168.1.10-100
o
subnet mask
255.255.255.0
o
gateway
192.168.1.1
► NTP
deactivated
► RSTP
deactivated
4.2.
First operation
Proceed as follows for the first commissioning:
Order No. 006-130-101/102
1. Connect the power supply
2. Connect the PC / notebook to one of the Ethernet ports 1-8 of the device
3. The connected PC / laptop must have the following network settings:
►
Order No. 006-130-101
IP address: 192.168.1.10/24
►
Order No. 006-130-102
IP address: get automatically
4. Start the web browser and enter the LAN-IP address of the device
5. Perform the desired configuration of the device
6. Connect the switch with your network devices