58
RL5000 S
ERIES
XS
CALE
AND
X2 A
UTOMATED
T
ELLER
M
ACHINES
S
ERVICE
M
ANUAL
Section 3
3. Refer to Figure 3-34. Con nect the TCP/IP (LAN) and any USB cables (if used)
to the X2 mainboard.
4. Push the AC pow er ON/OFF switch to the ON(I) position.
5. Close and lock the control pan el.
6. Verify that the ATM op er ates cor rect ly before plac ing it into ser vice.
M
AINBOARD
D
IAGNOSTIC
S
TATUS
AND
T
ESTING
M
AINBOARD
D
IAGNOSTIC
S
TATUS
V
ERIFICATION
The mainboard stores the Triton Standard XScale\X2 application program and
the Electronic Journal records in memory. It supports three (3) status LEDs that
monitor power (green), processor reset (red), and the Windows CE OS start up
process (amber).
The GREEN (+5v present) LED on the mainboard should immediately turn on
when power is applied to the terminal. If the GREEN LED on the mainboard
never turns on, there may be a problem with the mainboard, power, or the dock-
ing board.
The RED LED (processor reset) should turn on when power is applied to the
terminal and immediately go off. If the GREEN LED is on and the RED LED never
turns on, there may be a problem with the mainboard.
The AMBER LED (Windows CE OS start up) should turn on when power is ap-
plied to the terminal. It should stay on for approximately 5 second and then go
off. If the GREEN LED is on and the AMBER LED never turns on, there may be a
problem with the mainboard.
If the terminal fails to boot (white screen and/or the Triton Standard application
program fails to complete the start-up sequence), there may be a problem with
the mainboard or software (Windows CE OS or the front end of the application ).
**CAUTION**
When power is applied to the terminal, the display will be white (full back-
light). If it remains white, or the Triton application starts and then hangs
up, certain Windows OS or Triton XScale\X2 software system fi les may have
failed to load or are corrupted. This may happen if the terminal is not shut
down properly using Management Functions!
NEVER TURN OFF THE TERMINAL WITH THE AC POWER ON/OFF SWITCH UNLESS THE
XSCALE\X2 SOFTWARE APPLICATION HAS BEEN TERMINATED WITH MANAGEMENT
FUNCTIONS (SHUTDOWN THE TERMINAL)!
Содержание RL5000
Страница 2: ...ii RL5000 SERIES XSCALE AND X2 AUTOMATED TELLER MACHINES SERVICE MANUAL...
Страница 14: ...xiv RL5000 SERIES XSCALE AND X2 AUTOMATED TELLER MACHINES SERVICE MANUAL Preface...
Страница 18: ...1 SECTION 1 INTRODUCTION Section 1 SECTION 1 INTRODUCTION RL5000 Series XScale and X2 Automated Teller Machines...
Страница 19: ...2 RL5000 SERIES XSCALE AND X2 AUTOMATED TELLER MACHINES SERVICE MANUAL Section 1...
Страница 21: ...4 RL5000 SERIES XSCALE AND X2 AUTOMATED TELLER MACHINES SERVICE MANUAL Section 1...
Страница 22: ...5 SECTION 1 INTRODUCTION Section 1 Figure 1 1 The RL5000 Series XScale and X2 Automated Teller Machine...
Страница 29: ...12 RL5000 SERIES XSCALE AND X2 AUTOMATED TELLER MACHINES SERVICE MANUAL Section 2...
Страница 51: ...34 RL5000 SERIES XSCALE AND X2 AUTOMATED TELLER MACHINES SERVICE MANUAL Section 3...
Страница 162: ...145 INDEX Index INDEX...