background image

In the event of a product fault or complaint occurring, 
the following procedure should be followed:

DO NOT REMOVE THE PRODUCT

1.  Telephone Customer Experience on 

024 7637 2222

 having 

available your details including post code, the model number 
and power rating of the product, together with the date of 
purchase and, where applicable, details of the particular fault.

2.  If required, the Customer Experience Advisor will arrange for a 

qualifi ed engineer to call.

3.  All products attended to by a Triton service engineer must be 

installed in full accordance with the Triton installation guide 
applicable to the product. Every product pack contains an 
installation guide, however, they can also be downloaded free at 
www.tritonshowers.co.uk. 

4.  Our engineer will require local parking and if a permit is required, 

this must be available to the engineer on arrival at the call.

5.  If loft access is required for isolation or to complete a repair, 

the loft must have a fi xed access ladder and be boarded, with 
appropriate lighting from the access point to and around the 
repair area.

6.  It is essential that you or an appointed representative (who must 

be over 18 years of age) is present for the duration of the service 
engineer’s visit. If the product is in guarantee you must produce 
proof of purchase.

7.  Where a call under the terms of guarantee has been booked 

and the failure is not product related (i.e. scaling and furring, 
incorrect water pressure, pressure relief device operation or 
electrical/plumbing installation fault) a charge will be made. A 
charge will also be issued if nobody is at the property when the 
service engineer calls or adequate parking/permit is not available.

8.  If the product is no longer covered by the guarantee an 
 

up-front fi xed fee will be charged before the site visit.

9.  Your receipt must be retained as proof of purchase. Should proof 

of purchase not be available on an ‘in-guarantee’ call, or should 
the service engineer fi nd that the product is no longer under 
guarantee, the engineer will charge the same fi xed price and 
will request payment prior to departing. If payment is not made 
on the day an administration charge will be added to the fi xed 
charge.

10.  If a debt is outstanding from a previous visit, or from any other 

Triton purchase, Triton reserves the right to withhold service until 
the debt has been settled.

11.  Triton takes the health, safety and wellbeing of its employees 

very seriously and expects customers to treat all staff members 
with respect. Should any employee feel threatened or receive 
abuse, either verbally or physically, Triton reserves the right to 
withhold service.

Replacement Parts Policy

In line with AMDEA guidelines, Triton retains functional spares 
for as long as there is a market for them and in most cases, well 
beyond.  Due to the vast array of product types, the life cycle of 
products can vary and therefore so can the length of time parts 
can be supplied. Spare parts can be ordered via our online spare
parts store or by telephoning our Triton Customer Experience
team on 

024 7637 2222

. Payment should be made by

credit / debit card (excluding American Express or Diners Card).
Payment can also be made by pre-payment of a pro-forma
invoice, by cheque or postal order.

Telephone orders are based on information given during 
the call.  Before contacting Triton, please verify your 
requirements using the Information contained in the
user guide. Triton cannot accept liability for incorrect part 
identifi cation. 

TRITON UK STANDARD GUARANTEE

This guarantee applies only to products installed within 
the United Kingdom and does not apply to products used 
expressly for commercial gain, unless this use has been
specifi ed by Triton.  This guarantee does not affect your 
statutory rights.
With the exception of accessories, Triton guarantee the
product against all manufacturing defects for a period of 

5 years

 for use in a domestic environment from the date of 

purchase, provided that it has been installed by a competent 
person in full accordance with the fi tting instructions. 
All accessories such as shower heads, hoses and riser rails carry 

1 year

 parts only guarantee against manufacturing defects.

Any part found to be defective during this guarantee period 
we undertake to repair or replace at our option without 
charge, so long as it has been properly maintained and
operated in accordance with the instructions and has not 
been subject to misuse or damage or the effects of limescale 
build up. This product must not be taken apart, modifi ed or 
repaired except by a person authorised by Triton. 

What is not covered:

1.  Breakdown due to:  
 

a) 

use other than domestic use by the property 

occupants; 

b)

 wilful act or neglect; 

c) 

any malfunction resulting from the incorrect use or 

quality of electricity, gas or water or incorrect setting of 
controls; 

d) 

failure to install in accordance with this installation 

guide.

2.  Claims for missing parts once the product has been 

installed.

3.  Repair costs for damage caused by foreign objects or 

substances.

4.  Total loss of the product due to non-availability of parts.
5.  Compensation for loss of use of the product or 

consequential loss of any kind.

6.  Call out charges due to an abortive visit or where no fault 

has been found with the appliance.

7.  The cost of repair or replacement of isolating switches, 

electrical cable, fuses and/or circuit breakers or any other 
accessories installed at the same time. Replacement of the 
Pressure Relief Device that only activates when the shower 
outlet is blocked is also excluded. 

8.  The cost of routine maintenance, adjustments, overhaul 

modifi cations or loss or damage arising therefrom, 
including the cost of repairing damage, breakdown, 
malfunction caused by corrosion, furring, frost or exposure 
to freezing conditions.

9.  Call out charges where the water supply cannot be 

isolated, this includes consequential losses arising from

 

unserviceable supply valves, or inaccessible proudct or 
valves located in a loft space without suitable access.

For the latest Terms & Conditions please see:

www.tritonshowers.co.uk/terms

PLEASE NOTE PRODUCT REGISTRATION IS ONLY

AVAILABLE TO UNITS PURCHASED & INSTALLED IN THE UK

UK SERVICE POLICY

Triton Showers
Triton Road
Nuneaton
Warwickshire, CV11 4NR

Triton is a division of Norcros Group (Holdings) Limited

Customer Experience: 024 7637 2222

Trade Installer Hotline: 024 7637 8344

www.tritonshowers.co.uk

E-mail: [email protected]

E-mail: [email protected]

Triton reserve the right to change product specifi cation without prior notice. E&OE. © TRITON SHOWERS 2021

Содержание ELINA

Страница 1: ...EL 024 7637 8321 INSTALLATION AND OPERATING INSTRUCTIONS Please read this book thoroughly and familiarise yourself with all instructions before commencing installation and keep it for future reference...

Страница 2: ...mation CONTENTS Page MAIN COMPONENTS 1 INTRODUCTION 2 3 TYPICAL COMMERCIAL INSTALLATIONS 4 INSTALLATION 5 8 PREPARING THE SHOWER 5 SITING OF THE SHOWER 5 SUPPLY PIPEWORK 5 STRAIGHT FITTINGS 6 MAKING G...

Страница 3: ...Thermostatic bar mixer shower 1 MAIN COMPONENTS Ref Description 1 Elina bar mixer valve bottom exit 2 Straight connector X2 3 Bar Bracket push fit X2 if supplied with your product 1 Fig 1 2 3...

Страница 4: ...can provide nominally equal pressures at the mixer shower Water Minimum Flow Rate For best performance within the specified running pressure range a minimum flow of 8 litres per minute should be avail...

Страница 5: ...s not flushed through before fitting Commercial Applications It is recommended that for all commercial applications easily accessible in line filters are used to aid maintenance Hard Water Areas a If...

Страница 6: ...after the appliance reducing valve it will be necessary to fit an additional drop tight pressure reducing valve when the mains pressure is over 5 bar The drop tight pressure reducing valve MUST be set...

Страница 7: ...r fixing to a laminate cubicle or panel SITING OF THE SHOWER ACCESSORIES Refer to fig 4 for correct siting of the shower The mixer shower should be positioned as detailed with all controls within comf...

Страница 8: ...S The supply pipes can be routed from the side rising rear or falling and must end in suitable fittings to accept the long thread connectors fig 5 The straight connectors can be used to connect to BSP...

Страница 9: ...tions supplied with it FLOW REGULATION IMPORTANT Make sure that all supply pipework has been flushed through before fitting the mixer and flow regulators A flow regulator is supplied for use with high...

Страница 10: ...is may vary should be positioned so that it is at the 12 o clock position If fitted correctly the graphic and flow control should now be sitting in the designed OFF position Once in place fit the reta...

Страница 11: ...maximum temperature of 41 C and should be checked on site to guarantee user safety After setting the maximum temperature turn the shower on and off several times and check the maximum setting is corr...

Страница 12: ...erature setting Allow the shower to run at this maximum temperature setting until the water temperature has stabilised Rotate the temperature control until your desired maximum showering temperature i...

Страница 13: ...tish Burns Association recommends 37 C to 37 5 C as a comfortable bathing temperature for children In premises covered by the Care Standards Act 2000 the maximum mixed water outlet temperature is 43 C...

Страница 14: ...he water flow rotate the flow control clockwise until the water stops flowing fig 12 To adjust the water temperature rotate the temperature control right hand side clockwise for a cooler shower or ant...

Страница 15: ...0 This can be found laser marked onto the body of the mixer valve PRODUCT FLOW RATES For guidance only Flow Rate l m 3 5 5 4 7 4 8 9 10 0 15 0 22 0 26 6 30 8 34 6 Pressure bar 0 1 0 2 0 3 0 4 0 5 1 0...

Страница 16: ...Thermostatic bar mixer shower 14 296 00 1 2 BSP 49 00 5 0 5 0 3 4 BSP 185 00 150 00 All dimensions listed in this fitting book regarding the product and installation are approximate DIMENSIONS...

Страница 17: ...y from the previous test results e g 1 K 5 record the change and before re adjusting the mixed water temperature check that a that any in line or integral strainers are clean b any in line or integral...

Страница 18: ...r temperatures are recorded in only one of these periods necessitating adjustment of the mixed water temperature then the next in service test can be deferred to 24 to 28 weeks after commissioning c I...

Страница 19: ...ERVICE TESTING RECORD Where installed Mixer valve location Date installed Installed by Commissioning details Hot water Temp C Pressure Bar Cold water Temp C Pressure Bar Maximum temperature setting Te...

Страница 20: ...ery three months and clean if necessary b Perform a thermal shut off test every three months and check the maximum temperature setting See the Commissioning section for the details of this test and re...

Страница 21: ...d 2 6 Flow regulator not fitted HP systems only 3 1 Flow regulators not fitted 1 1 1 Refer to the Commissioning section 1 2 1 Reposition temperature control knob 1 3 1 Reposition temperature control k...

Страница 22: ...t the inlet filters Clean if necessary 4 3 1 Turn off the shower and consult a suitably competent plumber 4 4 1 Clean shower head 4 5 1 Reduce the simultaneous demand 4 5 2 Make sure stop service valv...

Страница 23: ...Thermostatic bar mixer shower 21...

Страница 24: ...ent of a pro forma invoice by cheque or postal order Telephone orders are based on information given during the call Before contacting Triton please verify your requirements using the Information cont...

Отзывы: