Thermostatic bar mixer shower

18

Cleaning

It is recommended that all products are cleaned 
using warm, soapy water.

Do not use abrasive or aggressive chemical 
cleaning products as this may affect the product 
surface finish and invalidate your guarantee.

Cleaning the Filters 

(fig.A)

It is advised that this should be carried out by a 

qualified person:

•  Turn off the water supplies before starting.

•  To gain access to the filters remove the unit 

from the inlet fittings.

•  Remove the filter housing and disassemble. 

•  Wash the filters thoroughly under running 

water, use a suitable brush to remove all debris.  

•  Reassemble and fit in reverse order.

WARNING!

DO NOT use powerful abrasive or  

solvent cleaning fluids when cleaning the 

shower as they may damage the fittings.

MAINTENANCE

Maintenance of the unit is required to give 
continued performance after installation and that 
it continues to provide scald prevention.

NOTE: 

A thermostatic mixing valve in need of 

maintenance can be undetectable in normal 
use and only becomes apparent when a 
disruption occurs in the hot or cold water 
supply temperatures or pressures.

It is a requirement that all 

TYPE 3

 approved 

valves shall be verified against the original set 
temperature results 

once every 12 months

.

 

a)  Initially check the filters for debris

 

once every 

three months and clean if necessary. 

b)  Perform a thermal shut off test every 

three months, and check the maximum 
temperature setting. See the Commissioning 
section for the details of this test and 
readjustment of the maximum temperature 
setting if required.

c)  If the maximum water temperature varies 

by more than 2°C from the commissioned 
setting then carry out the following checks

 

•  Check the isolating valves are fully open. 

 

•  Check the internal surface for scaling. 

If the body requires descaling then it should be 
removed from the pipework to carry this work 
out - all rubber parts 

MUST

 be removed before 

descaling.

 

• Check the function of the non-return valves.

The non-return valves (NRVs) prevent cross-flow 
between hot and cold supplies under unequal 
pressure conditions. They are designed for long 
life with no maintenance.

NOTE:

 The NRV’s will only operate in one 

direction - water should be able to flow into the 
unit from the inlets, but 

NOT

 back out through 

the inlets.

If these checks do not highlight the reason 
for the temperature variation, then internal 
components will require replacement - please see 
the Spare Parts list.

Disinfection

Where chlorine is used for the disinfection 
of water systems all relevant guidelines and 
approved codes of practice must be strictly 
followed. Failure to comply with the relevant 
guidelines and approved codes of practice may 
invalidate your guarantee.

Fig.A 

‘O’ ring

Filter

non-return valve

Filter housing

Note: 

the filter 

housing is 

Left 

hand thread.

Содержание ELINA

Страница 1: ...EL 024 7637 8321 INSTALLATION AND OPERATING INSTRUCTIONS Please read this book thoroughly and familiarise yourself with all instructions before commencing installation and keep it for future reference...

Страница 2: ...mation CONTENTS Page MAIN COMPONENTS 1 INTRODUCTION 2 3 TYPICAL COMMERCIAL INSTALLATIONS 4 INSTALLATION 5 8 PREPARING THE SHOWER 5 SITING OF THE SHOWER 5 SUPPLY PIPEWORK 5 STRAIGHT FITTINGS 6 MAKING G...

Страница 3: ...Thermostatic bar mixer shower 1 MAIN COMPONENTS Ref Description 1 Elina bar mixer valve bottom exit 2 Straight connector X2 3 Bar Bracket push fit X2 if supplied with your product 1 Fig 1 2 3...

Страница 4: ...can provide nominally equal pressures at the mixer shower Water Minimum Flow Rate For best performance within the specified running pressure range a minimum flow of 8 litres per minute should be avail...

Страница 5: ...s not flushed through before fitting Commercial Applications It is recommended that for all commercial applications easily accessible in line filters are used to aid maintenance Hard Water Areas a If...

Страница 6: ...after the appliance reducing valve it will be necessary to fit an additional drop tight pressure reducing valve when the mains pressure is over 5 bar The drop tight pressure reducing valve MUST be set...

Страница 7: ...r fixing to a laminate cubicle or panel SITING OF THE SHOWER ACCESSORIES Refer to fig 4 for correct siting of the shower The mixer shower should be positioned as detailed with all controls within comf...

Страница 8: ...S The supply pipes can be routed from the side rising rear or falling and must end in suitable fittings to accept the long thread connectors fig 5 The straight connectors can be used to connect to BSP...

Страница 9: ...tions supplied with it FLOW REGULATION IMPORTANT Make sure that all supply pipework has been flushed through before fitting the mixer and flow regulators A flow regulator is supplied for use with high...

Страница 10: ...is may vary should be positioned so that it is at the 12 o clock position If fitted correctly the graphic and flow control should now be sitting in the designed OFF position Once in place fit the reta...

Страница 11: ...maximum temperature of 41 C and should be checked on site to guarantee user safety After setting the maximum temperature turn the shower on and off several times and check the maximum setting is corr...

Страница 12: ...erature setting Allow the shower to run at this maximum temperature setting until the water temperature has stabilised Rotate the temperature control until your desired maximum showering temperature i...

Страница 13: ...tish Burns Association recommends 37 C to 37 5 C as a comfortable bathing temperature for children In premises covered by the Care Standards Act 2000 the maximum mixed water outlet temperature is 43 C...

Страница 14: ...he water flow rotate the flow control clockwise until the water stops flowing fig 12 To adjust the water temperature rotate the temperature control right hand side clockwise for a cooler shower or ant...

Страница 15: ...0 This can be found laser marked onto the body of the mixer valve PRODUCT FLOW RATES For guidance only Flow Rate l m 3 5 5 4 7 4 8 9 10 0 15 0 22 0 26 6 30 8 34 6 Pressure bar 0 1 0 2 0 3 0 4 0 5 1 0...

Страница 16: ...Thermostatic bar mixer shower 14 296 00 1 2 BSP 49 00 5 0 5 0 3 4 BSP 185 00 150 00 All dimensions listed in this fitting book regarding the product and installation are approximate DIMENSIONS...

Страница 17: ...y from the previous test results e g 1 K 5 record the change and before re adjusting the mixed water temperature check that a that any in line or integral strainers are clean b any in line or integral...

Страница 18: ...r temperatures are recorded in only one of these periods necessitating adjustment of the mixed water temperature then the next in service test can be deferred to 24 to 28 weeks after commissioning c I...

Страница 19: ...ERVICE TESTING RECORD Where installed Mixer valve location Date installed Installed by Commissioning details Hot water Temp C Pressure Bar Cold water Temp C Pressure Bar Maximum temperature setting Te...

Страница 20: ...ery three months and clean if necessary b Perform a thermal shut off test every three months and check the maximum temperature setting See the Commissioning section for the details of this test and re...

Страница 21: ...d 2 6 Flow regulator not fitted HP systems only 3 1 Flow regulators not fitted 1 1 1 Refer to the Commissioning section 1 2 1 Reposition temperature control knob 1 3 1 Reposition temperature control k...

Страница 22: ...t the inlet filters Clean if necessary 4 3 1 Turn off the shower and consult a suitably competent plumber 4 4 1 Clean shower head 4 5 1 Reduce the simultaneous demand 4 5 2 Make sure stop service valv...

Страница 23: ...Thermostatic bar mixer shower 21...

Страница 24: ...ent of a pro forma invoice by cheque or postal order Telephone orders are based on information given during the call Before contacting Triton please verify your requirements using the Information cont...

Отзывы: