Thermostatic bar mixer shower
19
The following can be carried out by a competent person
FAULT FINDING
1
Water too hot.
2
Water too cold.
3
High water flow
and/or poor
performance on a
mains fed system.
1.1
Temperature
control incorrectly
commissioned.
1.2
Not enough cold
water flowing through
shower.
1.3
Increase in the
ambient cold water
temperature.
1.4
Cold water supply
blocked.
1.5
High volume of cold
water drawn off
elsewhere.
2.1
Temperature control
incorrectly
commissioned.
2.2
Not enough hot water
flowing through
shower.
2.3
Decrease in the
ambient cold water
temperature.
2.4
Insufficient hot water
supplies from the
heating system.
2.5
Hot water supply
blocked or restricted.
2.6
Flow regulator not
fitted (HP systems
only).
3.1
Flow regulators not
fitted.
1.1.1
Refer to the Commissioning section.
1.2.1
Reposition temperature control knob
1.3.1
Reposition temperature control knob.
1.4.1
Turn off the shower and consult a
competent plumber or contact
Customer Experience.
1.5.1
Reduce the simultaneous demand from
the supply.
2.1.1
Refer to the Commissioning section.
2.2.1
Reposition temperature control knob
2.3.1
Reposition temperature control knob
2.4.1
Make sure heating appliance is set to
maximum or has sufficient stored hot water.
2.4.2
Make sure heating appliance is igniting by
trying a hot water tap elsewhere.
2.5.1
Turn off shower and consult a competent
plumber or contact Customer Experience.
2.6.1
Fit the supplied flow regulator - see Flow
Regulation section.
3.1.1
Fit the supplied flow regulator - see Flow
Regulation section.
Problem Cause
Action
Содержание ELINA