3

PLUMBING REQUIREMENTS

DO NOT

 use jointing compounds on any pipe 

fittings for the installation.

DO NOT

 solder fittings near the mixer shower 

as heat can transfer along the pipework and 
damage the shower.

DO NOT

 subject the unit to a water temperature 

above 80°C during installation, use, maintenance 
or disinfection.

IMPORTANT:

 

• 

The layout and sizing of pipework 

MUST

 

be such that nominally equal inlet supply 
pressures are achieved and the effects of 
other draw-offs are minimised.

• 

The pipework should be installed such 
that other taps and appliances being 
operated elsewhere on the premises do not 
significantly affect the flow

• 

When connecting pipework avoid using tight 
90° elbows; swept or formed bends will give 
the best performance.

• 

The hot water pipe entry 

MUST

 be made to 

the left-hand side inlet, marked HOT, ‘H’ or 
with a red/orange label.

• 

Suitable isolating valves (complying with 
Water Regulations and Bylaws) 

MUST

 be 

fitted on the hot and cold water supplies 
to the shower as an independent means 
of isolating the water supplies should 
maintenance or servicing be necessary; 
position as close as is practicable to the water 
supply inlets of the mixer shower. If this 
isolator is fitted in a loft space, the loft must 
have a fixed access ladder and be boarded, 
with appropriate lighting from the access 
point to the isolator.

• 

It is preferable to flush the pipework to clear 
the system of debris and check for leaks 
before connecting to the mixer.

• 

The mixer inlets contain removable filters 
that may become blocked if debris is not 
flushed through before fitting.

Commercial Applications

• 

It is recommended that for all commercial 
applications, easily accessible, in-line filters 
are used to aid maintenance.

Hard Water Areas

a.  If it is intended to operate the shower 

in areas of hard water (above 200-ppm 
temporary hardness), a scale inhibitor 
may have to be fitted. For advice on the 
scale inhibitor, please contact Customer 
Experience.

b.  For best performance the shower head 

MUST

 

be regularly cleaned to remove scale and 
debris.

WATER SYSTEM REQUIREMENTS

This mixer shower is suitable for:

•  Gravity water systems

•  Pumped gravity systems

•  Fully modulating type combination boilers

•  Multi-point hot water heaters

•  Thermal storage

•  Unvented systems

When installing this mixer with a combination or 
multi-point boiler, it may be necessary to install 
flow regulation. 

Check that the appliance is capable of delivering 
hot water at a minimum switch-on flow rate 
of 3 litres per minute. At flow rates between 3 
and 8 litres per minute, the appliance 

MUST

 be 

capable of raising the water temperature to 52°C 
minimum. 

Water temperature at the inlet of the mixer valve 

MUST

 remain relatively constant when flow rate 

adjustments are made - refer to the appliance 
operating manual to confirm compatibility with 
this mixer shower.

Where thermal store systems and instantaneous 
gas water heaters are used, if excessive draw-
off take place the appliance may not be able to 
maintain an adequate output temperature.  
This could result in the shower temperature 
becoming noticeably cooler.

Flow regulators can be fitted with high-pressure 
water systems to reduce flow rate and assist 
economy.

The hot supply temperature 

MUST

 remain a 

minimum of 10°C hotter than the required blend 
temperature for optimum performance.

Содержание ELINA

Страница 1: ...EL 024 7637 8321 INSTALLATION AND OPERATING INSTRUCTIONS Please read this book thoroughly and familiarise yourself with all instructions before commencing installation and keep it for future reference...

Страница 2: ...mation CONTENTS Page MAIN COMPONENTS 1 INTRODUCTION 2 3 TYPICAL COMMERCIAL INSTALLATIONS 4 INSTALLATION 5 8 PREPARING THE SHOWER 5 SITING OF THE SHOWER 5 SUPPLY PIPEWORK 5 STRAIGHT FITTINGS 6 MAKING G...

Страница 3: ...Thermostatic bar mixer shower 1 MAIN COMPONENTS Ref Description 1 Elina bar mixer valve bottom exit 2 Straight connector X2 3 Bar Bracket push fit X2 if supplied with your product 1 Fig 1 2 3...

Страница 4: ...can provide nominally equal pressures at the mixer shower Water Minimum Flow Rate For best performance within the specified running pressure range a minimum flow of 8 litres per minute should be avail...

Страница 5: ...s not flushed through before fitting Commercial Applications It is recommended that for all commercial applications easily accessible in line filters are used to aid maintenance Hard Water Areas a If...

Страница 6: ...after the appliance reducing valve it will be necessary to fit an additional drop tight pressure reducing valve when the mains pressure is over 5 bar The drop tight pressure reducing valve MUST be set...

Страница 7: ...r fixing to a laminate cubicle or panel SITING OF THE SHOWER ACCESSORIES Refer to fig 4 for correct siting of the shower The mixer shower should be positioned as detailed with all controls within comf...

Страница 8: ...S The supply pipes can be routed from the side rising rear or falling and must end in suitable fittings to accept the long thread connectors fig 5 The straight connectors can be used to connect to BSP...

Страница 9: ...tions supplied with it FLOW REGULATION IMPORTANT Make sure that all supply pipework has been flushed through before fitting the mixer and flow regulators A flow regulator is supplied for use with high...

Страница 10: ...is may vary should be positioned so that it is at the 12 o clock position If fitted correctly the graphic and flow control should now be sitting in the designed OFF position Once in place fit the reta...

Страница 11: ...maximum temperature of 41 C and should be checked on site to guarantee user safety After setting the maximum temperature turn the shower on and off several times and check the maximum setting is corr...

Страница 12: ...erature setting Allow the shower to run at this maximum temperature setting until the water temperature has stabilised Rotate the temperature control until your desired maximum showering temperature i...

Страница 13: ...tish Burns Association recommends 37 C to 37 5 C as a comfortable bathing temperature for children In premises covered by the Care Standards Act 2000 the maximum mixed water outlet temperature is 43 C...

Страница 14: ...he water flow rotate the flow control clockwise until the water stops flowing fig 12 To adjust the water temperature rotate the temperature control right hand side clockwise for a cooler shower or ant...

Страница 15: ...0 This can be found laser marked onto the body of the mixer valve PRODUCT FLOW RATES For guidance only Flow Rate l m 3 5 5 4 7 4 8 9 10 0 15 0 22 0 26 6 30 8 34 6 Pressure bar 0 1 0 2 0 3 0 4 0 5 1 0...

Страница 16: ...Thermostatic bar mixer shower 14 296 00 1 2 BSP 49 00 5 0 5 0 3 4 BSP 185 00 150 00 All dimensions listed in this fitting book regarding the product and installation are approximate DIMENSIONS...

Страница 17: ...y from the previous test results e g 1 K 5 record the change and before re adjusting the mixed water temperature check that a that any in line or integral strainers are clean b any in line or integral...

Страница 18: ...r temperatures are recorded in only one of these periods necessitating adjustment of the mixed water temperature then the next in service test can be deferred to 24 to 28 weeks after commissioning c I...

Страница 19: ...ERVICE TESTING RECORD Where installed Mixer valve location Date installed Installed by Commissioning details Hot water Temp C Pressure Bar Cold water Temp C Pressure Bar Maximum temperature setting Te...

Страница 20: ...ery three months and clean if necessary b Perform a thermal shut off test every three months and check the maximum temperature setting See the Commissioning section for the details of this test and re...

Страница 21: ...d 2 6 Flow regulator not fitted HP systems only 3 1 Flow regulators not fitted 1 1 1 Refer to the Commissioning section 1 2 1 Reposition temperature control knob 1 3 1 Reposition temperature control k...

Страница 22: ...t the inlet filters Clean if necessary 4 3 1 Turn off the shower and consult a suitably competent plumber 4 4 1 Clean shower head 4 5 1 Reduce the simultaneous demand 4 5 2 Make sure stop service valv...

Страница 23: ...Thermostatic bar mixer shower 21...

Страница 24: ...ent of a pro forma invoice by cheque or postal order Telephone orders are based on information given during the call Before contacting Triton please verify your requirements using the Information cont...

Отзывы: