Thermostatic bar mixer shower
11
TEMPERATURE ADJUSTMENT RANGE
The mixer has a temperature stop to prevent
accidental rotation to higher temperatures. This
is adjustable to provide a maximum temperature
of 35°C – 46°C.
The mixed water temperature can be adjusted
from cold through to a top limit (which can
be pre-set during installation – factory set
at approximately 38°C) with full anti-scald
protection throughout the range.
Recommended Outlet Temperatures
The
KIWA TYPE 3
scheme recommends a
maximum mixed water outlet temperature of
41°C for showers.
The mixed water temperatures must never
exceed
46°C
at terminal fitting.
The British Burns Association recommends
37°C
to
37.5°C
as a comfortable bathing temperature
for children. In premises covered by the Care
Standards Act 2000, the maximum mixed water
outlet temperature is
43°C
.
ADJUSTING THE MAXIMUM
TEMPERATURE STOP SETTING
Undo the retaining grub screw and pull the
temperature control off
(fig.10)
.
The maximum temperature stop does not need
to be removed.
Turn the flow control to full flow. With a steady
flow running, adjust the temperature spindle
until the temperature is about 38°C
(fig.11)
.
When the showering temperature is satisfactory
turn off the shower. Refit the temperature
control, making sure the graphic aligns as closely
to the to 12 o'clock as possible.
Secure the temperature control in place with the
retaining grub screw and fit the lever.
Fig.10
Fig.11
Temperature
spindle
Temperature STOP
Содержание ELINA
Страница 23: ...Thermostatic bar mixer shower 21...