68
Chapt
er 10
CHAPTER 10 - START-UP PREPARATION
10.5. Check For Gas Leaks
•
Prior to start-up and during initial operation,
check for a gas leak using a combustable gas
detector. Do not proceed with the start-up if
there is any indication of a gas leak. Any leaks
found must be repaired immediately.
•
Propane installations only - The propane
supplier mixes an odorant with the propane
to make its presence detectable. In some
cases the odorant can fade and the gas may
no longer have an odor.
•
Prior to start-up of the unit and periodically
after start-up have the propane supplier
check and verify the odorant level.
•
Failure to comply with these instructions
can result in substantial property damage,
serious injury, or death.
10.6. Check Thermostat Circuit
• Disconnect the external thermostat wires from the
low voltage terminals.
• Connect a voltmeter across the wire ends of the ex-
ternal thermostat wiring.
• Close each thermostat, zone valve and relay in the
external circuit one zone at a time and check the
voltage reading across the wire ends.
• There should NEVER be voltage measured at the
wire ends.
• If voltage is measured under any condition, check
and correct the external wiring.
WARNING
In systems using 3-wire zone valves, voltage
backfeed to the unit is a common problem. Use
an isolation relay to prevent voltage from the
external circuit from entering the INSTINCT.
• Reconnect the external thermostat wires to the low
voltage terminal strip.
10.7. Inspect Condensate Drain Assembly
1. Inspect and ensure the Condensate Drain Assembly
is properly installed as described in
Section 6.2 on
page 35.
2. Remove the plug from the Condensate Drain
Assembly and fill with fresh water.
The condensate drain assembly must be filled
with water when the INSTINCT is in operation.
The condensate drain assembly prevents flue
gas emissions from entering the condensate line.
Failure to ensure trap is filled with water can re-
sult in serious injury, or death.
3. Re-Install plug in condensate drain assembly.
NOTICE
WARNING
Содержание Instinct COMBI 155
Страница 2: ...INTENTIONALLY LEFT BLANK...
Страница 16: ...INTENTIONALLY LEFT BLANK...
Страница 24: ...INTENTIONALLY LEFT BLANK...
Страница 46: ...INTENTIONALLY LEFT BLANK...
Страница 54: ...INTENTIONALLY LEFT BLANK...
Страница 76: ...INTENTIONALLY LEFT BLANK...
Страница 86: ...INTENTIONALLY LEFT BLANK...
Страница 90: ...INTENTIONALLY LEFT BLANK...
Страница 92: ...INTENTIONALLY LEFT BLANK...
Страница 94: ...INTENTIONALLY LEFT BLANK...
Страница 122: ......
Страница 123: ......
Страница 124: ......
Страница 125: ......
Страница 126: ......
Страница 127: ......