EZ Setup
DHW EZ Setup
DHW Setpoint
140°F
68°F
168°F
DHW
Warmstart Temperature
125°F
86°F
Off
140°F
DHW
Warmstart Hysteresis
30°F
9
36°F
EZ Setup Complete
DHW EZ setup is complete.
Additional changes can be made in
the Installer Menu if required.
Press OK to return to EZ Setup Menu
57
CHAPTER
9
CHAPTER 9 - CTRLMAX OPERATION
DHW EZ Setup
prompts the installer to select the DHW setpoint.
DHW Setpoint
prompts to enter the fixed setpoint temperature
during a domestic hot water call.
Touch the
or
soft keys to adjust the temperature setpoint
then touch
to store the setting. The
DHW Warmstart Tempera-
ture
screen then appears .
Default: 140°F [60°C]
.
DHW Warmstart Temperature
prompts to enter the DHW tem-
perature in case you want to speed up the delivery of DHW in sum-
mer conditions.
Touch the
or
soft keys to adjust the temperature then touch
to store the setting. At the minimum temperature (86°F), this
function is OFF. The
DHW Warmstart Hysteresis
screen then ap-
pears .
Default: 125°F [52°C]
.
DHW Warmstart Hysteresis
prompts to enter the DHW hysteresis
value, comprised between 9°F (5K) and 36°F (20K).
Touch the
or
soft keys to adjust the hysteresis value, then
touch
to store the setting.
Default: 30°F (17k)
.
Altitude
must be correctly set to allow reliable operation of the
boiler.
From the home screen touch the
or
soft keys simultaneously for 5
seconds and “Enter Access Code” screen will be shown.
Touch the
or
soft keys to set the access code to 054. Touch
and the CH & DHW Settings creen will be shown.
Touch
and the CH Setting screen will be shown. Touch the
soft key and the “Boiler Settings” (list) screen will be shown.
Touch the
soft key until the “Altitude” option is highlighted. Touch
and the Altitude screen will be shown.
Touch the
soft key until the correct altitude is shown, then touch
the
soft key to highlight the home icon. Touch
to confirm.
Note. The altitude moves in steps of 984 ft (300m).
Domestic Hot Water EZ Setup allows the installer to quickly customize the Domestic Hot Water settings for the application
Standby
88°F
84°F
Target = - -
Combi
0 5 [4]
ENTER ACCESS CODE
CH & DHW Settings
CH Settings
Boiler Settings
Model
Instinct Combi
Lockout Temp.
Modbus Address
Pump Settings
Ignition level
Mix zone high limit
210ºF [99ºC]
1
300rpm
114ºF
Boiler Settings
Pump Settings
Altitude
0ft
Ignition level
Mix zone high limit
WP diff trigger
Appliance setting
3000 rpm
114ºF
0cpsi
Boiler Settings
Altitude
4920ft
0ft
19680ft
9.9. Domestic Hot Water EZ Setup
- INSTINCT Combi Units
9.10. Altitude Setup
Содержание Instinct COMBI 155
Страница 2: ...INTENTIONALLY LEFT BLANK...
Страница 16: ...INTENTIONALLY LEFT BLANK...
Страница 24: ...INTENTIONALLY LEFT BLANK...
Страница 46: ...INTENTIONALLY LEFT BLANK...
Страница 54: ...INTENTIONALLY LEFT BLANK...
Страница 76: ...INTENTIONALLY LEFT BLANK...
Страница 86: ...INTENTIONALLY LEFT BLANK...
Страница 90: ...INTENTIONALLY LEFT BLANK...
Страница 92: ...INTENTIONALLY LEFT BLANK...
Страница 94: ...INTENTIONALLY LEFT BLANK...
Страница 122: ......
Страница 123: ......
Страница 124: ......
Страница 125: ......
Страница 126: ......
Страница 127: ......