4)
Horizontal Terminal Installation
a) Cut a 6-1/2”
diameter hole for the 100/150 terminal through the exterior wall at the planned location of the
horizontal terminal.
b) Measure distance “L” from the outside surface of the exterior wall to the end of the last fitting as shown in
Figure 6.20a.
c) Add 1-1/4” to distance “L”. Carefully mark this length on the pipe as shown in Figure 6.20b.
d) Remove the aluminum inner pipe from the terminal, by gently pulling on it from the male end. Set aside.
e) Cut the
outer pipe only
at the point marked in Step (c) using aviation shears, a hacksaw, or an abrasive
wheel cutter. Be careful to cut the pipe square. De-burr the cut end with a file or emory cloth.
f) Reinstall the aluminum inner pipe in the terminal, making sure that the female end of this pipe is
completely bottomed out over the aluminum male connection visible behind the air intake grill. Place a
mark on the aluminum inner pipe 3/8” beyond the end of the outer pipe (Figure 6.20c). Use a fine tooth
hacksaw or hand shears to cut the aluminum pipe and be careful to cut the pipe square (if necessary, the
aluminum pipe can be removed from the terminal again for cutting). De-burr the cut edge of the aluminum
pipe with a file or fine sandpaper.
g) Make a mark on the terminal section 1” from the cut end of the outer pipe as shown in Figure 6.20c.
h) Slip the terminal section through the wall from the outside. Pass the terminal through the inner wall plate
and push into the last section of vent pipe until the mark made in Step (h) is no longer visible (Figure
6.20d). Secure the terminal to the last piece of pipe with three #10 x 1/2” sheet metal screws. Drill a 1/8”
hole through both outer pipes to start these screws.
Use a drill stop or other means to ensure that the
drill bit does not penetrate more than 3/8” into the outer pipe. Do not use a sheet metal screw longer
than 1/2”.
i) Slip the outer wall plate over the terminal and secure to the wall (Figure 6.20d). Apply a 1/8” bead of
weather resistant RTV over the joint between the outside wall plate and the terminal. Secure the other wall
plate to the inside wall.
FIGURE 6.20a: DIMENSION “L”, HORIZONTAL TERMINAL
FIGURE 6.20b: CUTTING OUTER PIPE OF HORIZONTAL TERMINAL
26
Содержание Triumph series
Страница 2: ......
Страница 31: ...29 FIGURE 6 21b CUTTING VERTICAL TERMINAL FIGURE 6 21c COMPLETING VERTICAL TERMINAL INSTALLATION ...
Страница 34: ...32 FIGURE 6 23 CONDENSATE PIPING ARRANGEMENT ...
Страница 48: ...46 Figure 8 14 Multiple Boiler Piping ...
Страница 50: ...Figure 9 1 Wiring Connections Diagram 48 ...
Страница 51: ...Figure 9 2 Ladder Diagram 49 ...
Страница 69: ...67 PAGE INTENTIONALLY LEFT BLANK ...
Страница 71: ...69 ...
Страница 72: ...70 ...
Страница 73: ...71 ...
Страница 75: ...73 ...
Страница 76: ...74 ...
Страница 78: ...76 ...
Страница 79: ...77 ...
Страница 82: ...80 ...
Страница 83: ...81 155 156 158 157 160 159 ...
Страница 84: ...82 161 162 164 163 166 165 ...
Страница 85: ...83 167 ...