Approved Vent Configurations
Maximum Vent Run and Rise
The fireplace vent must meet the following requirements:
Maximum Horizontal Run = 100’ (30 M)*
Maximum Vertical Rise = 140’ (42 M)*
Maximum
90˚ Elbows = 4 (note: two 45˚ elbows count as one 90˚ elbow)
Maximum Vertical Drop = 3’ (1 M) Below base of fireplace
Minimum Vent Length = 54” (1372mm)
* Those installations with a total vent length over 140’ (42 M), contact Travis Industries for further review
and approval.