22 Installation
(for qualified installers only)
© Travis Industries
4140717
100-01351
Wiring the Exhaust Blower
Do not connect 110-120 VAC to the gas control valve or wiring system of this fireplace.
The exhaust box is wired to the 120v line exiting the exhaust blower rheostat. Connect a minimum 12
gauge sheathed three-wire electrical line from the rheostat to the exhaust blower junction box. Attach
the wires as shown below.
Test blower operation after attaching the wiring (leave gas off, turn appliance on, verify blower
functions correctly).
Remove the cover plate on the exhaust blower
housing.
Route the electrical line through the romex
connector and attach the 120v wiring as detailed in
the wiring diagram.
Romex
Clamp
Fireplace Junction Box
Molex (installed
in
fireplace)
Exhaust Blower Junction Box
Black
White
Green
White
Capacitor
Green
Black
Black
Black
Black
White
Green
Red
Blower