![Travis Industries Xtreme 6020 Скачать руководство пользователя страница 26](http://html.mh-extra.com/html/travis-industries/xtreme-6020/xtreme-6020_installation-manual_1154149026.webp)
26 Installation
(for qualified installers only)
© Travis Industries
4140717
100-01351
Air Inlet Installation (continued)
Before attaching the flex duct, make sure to
attach the inlet damper wires to the damper
assembly. Then insert the wires into the flex
duct. Pull the wires through the duct, making
sure they do not catch any sharp edges.
Slide the flex duct into place.
NOTE
: In the pictured example, we have
crimped the inlet damper. You may crimp this
or use the included slider plate or connector to
attach your flex duct.
Secure the flex duct to the inlet damper with two
screws
DO NOT SCREW INTO THE TOP OF THE
INLET DAMPER – THIS MAY CAUSE
DAMAGE TO THE INLET DAMPER
ACTUATOR.
Use suitable tape to seal the duct joint.
Route the flex duct to the fireplace air inlet.
Connect the wires from the air inlet damper to
the wires from the fireplace.
NOTE
: The air inlet wires may be shortened to
ease installation.