5.3 Replacement Procedures
WARNING: SwitchMaster™ Units contain no user-serviceable parts.
Except for the installation or replacement of X Slot Cards, DO NOT,
UNDER ANY CIRCUMSTANCES, open and attempt to repair
SwitchMaster™ equipment. Failure to observe this warning could result
in electrical shock and personal injury.
NOTE: Failure to observe the above warning will immediately void any
warranty.
Replacing SwitchMaster™ Bridge Fuses
To replace a SwitchMaster™ Unit fuse:
1. Disconnect outlet end of power cord from AC wall socket.
2. Disconnect the power cord from the SwitchMaster™ Unit power
receptacle.
3. Carefully open fuse receptacle, using small flat blade screwdriver.
CAUTION: Replace fuse only with same size and rating. Failure to
observe this caution could result in equipment damage.
NOTE: Installed fuse rating orientation is indicated by reading in lower
right corner of fuse holder.
4. Install replacement fuse holder in correct rating orientation.
5. Close fuse receptacle.
6. Connect power cord to SwitchMaster™ Unit power receptacle.
7. Connect outlet end of the power cord to the AC wall socket.
8. Verify that POWER LED at the front of the SwitchMaster™ Unit is
illuminated.
5-5
EIGHT SEGMENT BRIDGE
5. MAINTENANCE
110-120
110-120
220-240
220-240
110-120 Orientation
220-240 Orientation
Fuse Holder