3-7
EIGHT SEGMENT BRIDGE
3. INSTALLATION
3.4
Connecting to Power
To connect the SwitchMaster™ Bridge to power:
1. At SwitchMaster™ Bridge back, locate the power receptacle and
associated fuse.
CAUTION: Fuse must be installed at correct setting for power source
voltage before connecting to AC voltage. Failure to observe this caution
could result in equipment damage.
2. Verify that the fuse is installed at the correct setting for power source
voltage.
NOTE: Installed fuse rating orientation is indicated by reading in lower
right corner of fuse holder.
If not installed at correct setting:
•
Carefully open fuse receptacle, using small flat blade
screwdriver.
•
Rotate fuse 180º to correct rating orientation.
•
Install fuse holder in correct rating orientation.
•
Close fuse receptacle.
3. Plug female unit end of power cord into SwitchMaster™ Bridge power
receptacle.
4. Plug male outlet end of power cord into correct voltage AC wall
socket.
5. At SwitchMaster™ Bridge front, verify that the POWER LED is
illuminated.
When the SwitchMaster™ Bridge is powered, Status LEDs at the
SwitchMaster™ Bridge front cycle during internal SwitchMaster™ Bridge
diagnostic testing. The Status LEDs cycle in a steady roll when the
SwitchMaster™ Bridge is fully operational.
110-120
110-120
220-240
220-240
110-120 Orientation
220-240 Orientation
Fuse Holder
Fuse Holder