Page 37 of 57
Table VIII Honeywell
SSD120
DA-15P
Conn.
Function
Honeywell
Bendix/King
560EGPWS
&
MK-XXI EGPWS
Honeywell
Bendix/King
KGP 860
GA-EGPWS
Honeywell
Bendix/King
KMH 870
IHAS
Processor
1
D4
No connection
No Connection
18
2
A1 12 J1-12
11
3
A2 52 J1-52
10
4
A4 33 J1-33 9
5
B1 14 J1-14
14
9
B2 34 J1-34
13
10
B4 73 J1-73
12
11
C1 32 J1-32
17
13
C2 13 J1-13
16
12
C4 72 J1-72
15
6
Output
Enable
Connect to aircraft
ground
Connect to
aircraft ground
Connect to
aircraft ground
8 or
14*
14
+14 to
28Vdc
Connect to avionics
buss via circuit
breaker
Connect to
avionics buss
via circuit
breaker
Connect to
avionics buss
via circuit
breaker
15
Ground
Connect to aircraft
ground
Connect to
aircraft ground
Connect to
aircraft ground
The Honeywell Bendix/King 860 EGPWS manual lists an RS232 serial altitude data input on pin
J1-45 with a data common on pin J1-46. Several TCI compatible serial data protocols are listed,
but at the time of this printing, Trans-Cal has not tested the 860 EGPWS data input for
compatibility.
14
Pins 8 and 14 are connected internally.
Содержание SSD120-N-RS5
Страница 17: ...Figure 1 Altitude Digitizer Correspondence Page 17 of 57...
Страница 19: ...Figure 2 Dynamic Calibration Set Up Using the ECP 100 Page 19 of 57...
Страница 50: ...Wiring Harness Diagram Part Number 881404 50...
Страница 51: ...Span Adjust Block Diagram 51...
Страница 52: ...Dynamic Calibration Block Diagram 52...
Страница 53: ...Figure 2 Temperature vs Warm up Time TEMPERATURE Degrees Celsius Seconds 20 TIME 53...
Страница 54: ...Outline Drawing 54...