4.7 Serial Port Software Configuration
The SSD120-(XX)N-RS5 incorporates five RS232 compatible outputs, which are configured into
two groups. The two serial data groups may be configured via software to transmit two (2) different altitude
data protocols simultaneously.
Connect the digitizer to an IBM compatible computer running
HyperTerminal
as described in
§4.5
and as shown in the
Dynamic Calibration Block Diagram.
Assign the serial port protocols as follows:
Apply power to the digitizer and after the self-test time has elapsed, altitude data will appear on the
PC screen.
Type
<enter>
The digitizer will respond with
?>(current altitude)
Type
ADJ<enter>
Accesses the
digitizer adjustment program.
The Digitizer responds
A=
Type
P<enter>
To identify the current serial port settings.
The digitizer will respond with a three-digit number as follows:
a b c
Page 21 of 57
Serial Altitude Data Resolution
TxD4 & 5 Protocol
TxD1 thru 3 Protocol
1.
The first digit represents the serial altitude data resolution.
0 = Use D-Sub connector protocol hardware jumpers.
1 = 100 foot resolution on all serial outputs.
2 = 10 foot resolution on all serial outputs.
2.
The second digit represents the protocol selection for TxD1, TxD2 and TxD3.
0 = Use D-Sub connector protocol hardware jumpers.
1 = UPS Aviation Technologies. 1200bps.
2 = Trimble/Garmin. 9600bps.
3 = Northstar. 2400bps.
4 = Magellan, 1200bps.
5 = ARNAV, 9600bps.
6 = UPS AT 618 Loran 1200 bps. (IIMorrow)
3.
The third digit represents the protocol selection for TxD4 & TxD5.
0 = Use D-Sub connector protocol hardware jumpers.
1 = UPS Aviation Technologies. 1200bps.
2 = Trimble/Garmin. 9600bps.
3 = Northstar. 2400bps.
4 = Magellan, 1200bps.
5 = ARNAV, 9600bps.
6 = UPS AT 618 Loran 1200 bps. (IIMorrow)
Software Configuration Example: Type
P215<enter>
Defined as
10 foot
resolution on all serial data.
UPS Aviation Technologies
protocol transmitted on TxD1, TxD2 & TxD3.
ARNAV Systems
protocol transmitted on TxD4 & TxD5.
Содержание SSD120-N-RS5
Страница 17: ...Figure 1 Altitude Digitizer Correspondence Page 17 of 57...
Страница 19: ...Figure 2 Dynamic Calibration Set Up Using the ECP 100 Page 19 of 57...
Страница 50: ...Wiring Harness Diagram Part Number 881404 50...
Страница 51: ...Span Adjust Block Diagram 51...
Страница 52: ...Dynamic Calibration Block Diagram 52...
Страница 53: ...Figure 2 Temperature vs Warm up Time TEMPERATURE Degrees Celsius Seconds 20 TIME 53...