Page 24 of 57
(
S10
represents
Set 10,000 feet
)
The digitizer will now output 10,000 feet based on the current
input pressure.
The PC will display the altitude at which the digitizer will make this change. In the
example referenced above, the PC would display
>10000.
18. Proceed to the next 1000-foot mark and repeat the procedure, as in step 8 above, until the
entire operating range of the digitizer is completed.
Note:
a) If no correction is required at an altitude simply do not enter a correction.
b) Do not adjust the high or low potentiometers during this procedure.
c) You may quit the adjustment program at any time by typing
“
Q
”
twice; the digitizer
output will then be displayed on the PC screen in normal operation mode.
19. After completing the above procedure you may examine the corrections entered into the
EEPROM. Type “
D<enter>
” to display the EEPROM data and read the current error curve
on the PC screen. The following table should appear:
00= 000
01= 000
02= 000
03= 000
04= 000
05= 000
06= 000
07= 000
08= 000
09= 000
10= 000
11= 000
12= 000
13= 000
14= 000
15= 000
16= 000
17= 000
18= 000
19= 000
20= 000
21= 000
22= 000
23= 000
24= 000
25= 000
26= 000
27= 000
28= 000
29= 000
30= 000
31= 000
32= 000
33= 000
34= 000
35= 000
36= 000
37= 000
38= 000
39= 000
40= 000
41= 000
42= 000
43= 000
44= 000
45= 000
90= 000
91= 000
92= 000
93= 000
94= 000
95= 000
96= 000
97= 000
98= 000
99= 000
>current altitude
The first two digits represent altitude x1000 feet and the last three digits after the equal sign represent the
amount of error introduced at the altitude in feet.
Note:
Fields
90 = 000
through
99 = 000
contain TCI calibration data and are not user accessible.
Содержание SSD120-N-RS5
Страница 17: ...Figure 1 Altitude Digitizer Correspondence Page 17 of 57...
Страница 19: ...Figure 2 Dynamic Calibration Set Up Using the ECP 100 Page 19 of 57...
Страница 50: ...Wiring Harness Diagram Part Number 881404 50...
Страница 51: ...Span Adjust Block Diagram 51...
Страница 52: ...Dynamic Calibration Block Diagram 52...
Страница 53: ...Figure 2 Temperature vs Warm up Time TEMPERATURE Degrees Celsius Seconds 20 TIME 53...
Страница 54: ...Outline Drawing 54...