4.10 Serial Port Software Configuration Using the ECP-100
This procedure will allow the technician to assign separate serial data output protocols to the altitude
digitizer output port groups. Connect the ECP-100 to the altitude digitizer as shown in
Figure 3
.
Step 1:
With the
ECP-100
and altitude encoder power
off
, Slide the CAL. Program switch to its
rightmost
PROGRAM
position and connect the ECP-100 to the altitude encoder, as shown in
Figure
3
.
Step 2:
With the
ECP-100
power switch in the
OFF
position, apply power to the altitude encoder,
then slide the
ECP-100
power switch to the on position. The
ECP-100
will beep twice then display
the current pressure altitude transmitted from the altitude digitizer.
ALTITUDE PROGRAMMER
ALT 00800
Step 3:
Push the
READ SET-UP DATA
pushbutton once. The
ECP-100
will display the current serial
port protocol settings for 15 seconds, and then return to the altitude programmer display page. The
factory setting is pictured below.
DATA = 000
100 Foot Resolution
TxD1= UPS 1200bps
TxD2= UPS 1200bps
TxD1 on the ECP-100 will set the serial data protocol for TxD1, TxD2 and TxD3. While TxD2 on the
ECP-100 will set the Serial data protocol for TxD4 and TxD5.
Step 4:
Slide the
RESOLUTION
selector to the desired altitude data resolution 10’ or 100’.
Step 5:
Rotate the TxD1 and TxD2 selector knobs to the desired output protocol. For the purpose of
this example we will set TxD1 to transmit the UPS protocol and TxD2 to transmit the Trimble/Garmin
protocol.
Step 6:
Press the
INITIATE PROGRAM
pushbutton once. The display will beep then flash
PROGRAMMING and display the protocols to be programmed. Wait until the
ECP-100
emits a long
beep and displays OPERATION COMPLETED then returns to the ALTITUDE PROGRAMMER
display.
PROGRAMMING
10 Foot Resolution
TxD1= UPS 1200bps
TxD2= Trimble/Garmin
Step 7:
Confirm the port programming by pressing the
READ SET-UP DATA
pushbutton. It should
display the settings applied in the previous steps. In the case of our example the display would
appear as below.
DATA=212
10 Foot Resolution
TxD1= UPS 1200bps
TxD2= Trimble/Garmin
Page 25 of 57
Содержание SSD120-N-RS5
Страница 17: ...Figure 1 Altitude Digitizer Correspondence Page 17 of 57...
Страница 19: ...Figure 2 Dynamic Calibration Set Up Using the ECP 100 Page 19 of 57...
Страница 50: ...Wiring Harness Diagram Part Number 881404 50...
Страница 51: ...Span Adjust Block Diagram 51...
Страница 52: ...Dynamic Calibration Block Diagram 52...
Страница 53: ...Figure 2 Temperature vs Warm up Time TEMPERATURE Degrees Celsius Seconds 20 TIME 53...
Страница 54: ...Outline Drawing 54...