110
TRAK Machine Tools
Southwestern Industries, Inc.
ProtoTRAK SMX, K2, K3 & K4 & Retrofit Safety, Installation, Maintenance, Service and Parts List Manual
6.3 Suggested Fastener Stock
It is suggested that the ProtoTRAK installer have on hand the following fasteners in the event that they are inadvertently
left out of the kit or lost during installation:
Qty
Fastener
8
5/16-18”x1 1/2” shcs, ballnut to yoke (BP)
6
10-32x3/8 shss, ballnut oil plug
7
1/4-20x1” hhcs, bearing housing to drive housing bracket
4
3/8-16x2 1/2 shcs, drive bracket to table
4
oil line elbow, 15187
4
brass fitting, 15696
2
T-fitting, P2 TUB-2
10
Washers, 15759
1
3/8-24 screw, 16355-1
6
Spacer, 14772
6
8-32x3/8: shcs, mounting bracket plate
3
8-32x7/8 round head Phillips
2
1/2-20 nut
4
Washer, flat 3/8, 98017A200
2
Lockwasher, 91114A033
12
6-32x3/8 flat head Phillips
3
5/16-18x2 shss
2
5/16-18x1 shcs
1
M10-1 screw, 16364-1
1
M10-1.5 screw, 16364-2
1
M10-1.5 screw, 16355-2
2
10-32x1
1
5/8-11 nut
3
M6 x 20 shcs – used to mount cable breakout box
TRAK Machine Tools offers a complete set of spare fasteners and spare parts for ProtoTRAK installers at a special price.
Contact the Customer Service Group for details.
6.4
Pre-Installation Requirements
*
Power requirements: 115V, 60Hz, 1100VA, 12-amp power line dedicated to the ProtoTRAK.
*
Adequate working area around the machine to slide the table completely off the saddle.
*
Availability of a lift table or cart capable of supporting the table once it is removed from the machine.