![TR-Electronic MP-200 Скачать руководство пользователя страница 67](http://html.mh-extra.com/html/tr-electronic/mp-200/mp-200_user-manual_1146662067.webp)
Printed in the Federal Republic of Germany
TR-Electronic GmbH 2016, All Rights Reserved
09/29/2020
TR-EMO-BA-GB-0022 v03
Page 67 of 153
In order to ensure safe, fault-free operation,
-
ISO/IEC 11801, EN 50173 (European standard)
-
ISO/IEC 8802-3
-
and other pertinent standards and directives must be complied with!
In particular, the applicable EMC directive and the shielding and grounding directives
must be observed!
7 Optional holding brake / ballast circuit
If the motor is equipped with a holding brake, the brake output voltage 0x2F04:05
must be set according to its rating. Otherwise it may be overloaded or may not open.
If a ballast resistor is attached to the open drain ballast output, the limit of the ballast
output voltage 0x2F04:06 must be set according to its rating. Otherwise the resistor
may be overloaded or become ineffective.
The effective ballast output voltage is regulated by PWM. If the DC link voltage
0x6079 exceeds the ballast input voltage threshold 0x2F04:07, it increases linearly
and reaches the rated value 0x2F04:05, as soon as the excess DC link voltage is
equal to the full ballast input voltage 0x2F04:08.
8 Commissioning
8.1 Device description file
The XML file contains all information on the drive-specific parameters and the
operating modes of the drive. The XML file is integrated by the EtherCAT network
configuration tool, in order to enable correct configuration and commissioning of the
drive.
Download:
www.tr-electronic.de/f/TR-EMO-ID-MUL-0018