0x63FE
A ratio had to be corrected, because it was infinite or 0. Numerator and
denominator may have both changed.
0x63FF
A range had to be corrected, because the upper limit was not larger than the
lower one. The stroke equals 1 + upper limit - lower limit and must have at least 2
increments. Lower and upper limit may have both changed.
0x7000
Additional modules
– generic error
0x7300
Main disk sensor failed:
too much consecutive read errors -> fatal fault
0x731F
Gear disk sensors failed:
too much consecutive read errors -> fault if not calibrating
0x7320
Position sensor failed: absolute and incremental
position doesn’t fit.
Possible causes: missing calibration, broken gear -> fault if not calibrating
If the offset of a satellite disk exceeds the adjustment tolerance, an emergency
warning n is sent, where n is the satellite number. This means that the gear
disk calibration should be repeated. But unless there is an emergency 0x7300 or
0x7320, the current position or velocity ramp can be finished safely.
0x732F
Warning: the gear disks have only been calibrated quickly. Then the function of the
gear can't be guaranteed, because the full measuring range obviously has not been
tested, and exceeding the tolerances is more probably due to the poor
accuracy of the quick calibration.
0x7330
If not calibrating the gear disks: Bad or missing calibration of the gear disks.
-> fault if not calibrating anything.
During the gear disk calibration: AS5040/45 linearity error due to a magnetic field that
is out of range: missing magnet, magnet too is close or too far away.
-> fault
Actually the emergencies n are sent, where n is the gear disk number from 1
to GEARDISKS_MAX. 0 is the main disk.
0x73F0
If not calibrating the gear disks: Bad or missing calibration of the gear disks.
-> fault if not calibrating anything.
During the gear disk calibration: AS5040/45 linearity error due to a magnetic field that
is out of range: missing magnet, magnet too is close or too far away.
-> fault
Actually the emergencies n are sent, where n is the gear disk number from 1
to GEARDISKS_MAX. 0 is the main disk.
0x73E0
Warning: the gear disks have only been calibrated quickly. Then the function of the
gear can't be guaranteed, because the full measuring range obviously has not been
tested, and exceeding the tolerances is more probably due to the poor
accuracy of the quick calibration.
0x8000
Monitoring
– generic error
0x8100
Monitoring, communication
– generic error
0x8110
Monitoring, CAN overrun (loss of messages)
0x8120
Monitoring, CAN switched to error passive
0x8130
Monitoring, Life-Guard error or Heartbeat error
0x8140
Monitoring, recovered from bus off
0x8150
Monitoring, collision of the CAN-ID
0x8200
Protocol error
– generic error
. . .