Parameterization and configuration
TR-Electronic GmbH 2009, All Rights Reserved
Printed in the Federal Republic of Germany
Page 78 of 92
TR - ELA - BA - DGB - 0015 - 13
04/23/2020
Overview of operating parameters
see note on page 72
Parameter
Data type
Byte
Format
Description
Interpolation
bit
x+0
Counting direction
bit
x+0
Resolution
unsigned16
x+1
– x+2
Number of magnets
bitarea
x+3
Observer
unsigned8
x+4
Averaging
unsigned8
x+5
Unit v
unsigned32
x+6
– x+9
Option 1
unsigned16
x+10
– x+11 page 80
Option 2
unsigned32
x+12
– x+15
in preparation
Bit coded operating parameters
Byte
X+0
Bit
7
– 0
Data
2
7
– 2
0
x = default setting
Bit Definition
= 0
= 1
Page
0
Interpolation
off
X
on
1
Counting direction
increasing position values
to the rod end
X
decreasing position
values to the rod end
Operating parameter Resolution
Description see page 82
unsigned16
Byte
X+1
X+2
Bit
15
– 8
7
– 0
Data
2
15
– 2
8
2
7
– 2
0
Default (dec.)
5 µm (1…1000)
Resolution