4.1 Connection
PORT 1
Flange socket M12x1-4 pin D-coded
Pin 1
TxD+, transmitted data +
Pin 2
RxD+, received data +
Pin 3
TxD
–, transmitted data –
Pin 4
RxD
–, received data –
PORT 2
Flange socket M12x1-4 pin D-coded
Pin 1
TxD+, transmitted data +
Pin 2
RxD+, received data +
Pin 3
TxD
–, transmitted data –
Pin 4
RxD
–, received data –
Supply
Flange connector M8x1-4 pin or M12x1-4
Pin 1
19
– 27 V DC
Pin 2
1)
TR
Pin 3
GND, 0 V
Pin 4
1)
TRWinProg
–
1
3
2
4
Shielded twisted pair cables must be used for the supply !
Order data for Ethernet flange socket M12x1-4 pin D-coded
Manufacturer
Designation
Order no.:
Binder
Series 825
99-3729-810-04
Phoenix Contact
SACC-M12MSD-4CON-PG 7-SH (PG 7)
15 21 25 8
Phoenix Contact
SACC-M12MSD-4CON-PG 9-SH (PG 9)
15 21 26 1
Harting
HARAX
M12-L
21 03 281 1405
1)
for service purposes, e.g. software update