6.4.6 Averaging
With this
the output position value can be averaged and results in a small
output jitter.
Lower limit
0
Upper limit
16
Default
0
● Averaging 0, 1: no averaging
● Averaging 2: averaging of 2 values
● …
● Averaging 16: averaging of 16 values
6.4.7 Unit v
With this parameter the resolution of the Velocity output in 0.01 mm/s is determined.
Lower limit
1:
1/100 mm/s
Upper limit
100 000: 1 m/s
Default
100:
1 mm/s
6.4.8 Option 1 (Diagnostic alarm - control)
This function is not supported at Soft. No. 5619 !
If a measurement error is present, with this parameter the behavior of the
Diagnostic alarm
can be controlled, see chapter 7.2 on page 89.
Lower limit
Bit 0 = 0:
In case of a measurement error only the
Data status
is set to
BAD
Upper limit
Bit 0 = 1:
In case of a measurement error the
Data status
is set to
BAD
and additionally a
Diagnostic alarm
is executed.