Installers Information
FLUE COLLAR POSITION OPTIONS
Ehaust
Default
possition
Flue Collar Position
The HeliFire 360 is shipped with the flue collar attached to the end of the
unit (Figure 62). The flue collar can be relocated to either side of the unit.
To change exhaust vent position:
1. Remove the flue collar from the exhaust end of the HeliFire 360.
2. Remove the cover plate from the desired side of the HeliFire 360 and
secure the flue collar to that opening.
3. Secure the left over cover plate to the exposed opening.
Note: The combustion air intake collar is located at the opposite end
of the HeliFire 360 body and cannot be relocated.
Figure 62: Exhaust position options.
Ceiling or Floor Firestop
Where the exhaust vent pipe passes through a ceiling or floor, a firestop must be used to maintain a seal and proper
clearances.
NOTE
1 pair of Firestop come with the surface mounted power vent kit
and the Flush mount vent kit. Use as many firestops as is necessary
to maintain a 1/4 inch clearance between the flexible vent and any
combustible material throughout the length of the exhaust portion
of the flexible vent. If additional firestops are required, packages
of 2 pair can be ordered through a Town & Country Retailer - See
“Replaceable Parts” on page 32.
Figure 63: HeliFire 360 Firestops.
29
5055.64-A
TCHF.22bodyA_ 090617-36
TCHF.22STbodyA