Figure 54: Surface mount
power vent detail.
Use the Surface mount power vent
unit (Figure 54) if the power vent is to
be located on the roof of a structure
(Figure 48). The Surface mount power
vent unit can also be used on a wall.
The Surface mount power vent unit
must use the HeliFire 360 inlet vent
box.
Use the Flush mount power vent on
outside vertical walls only. The Flush
mount power vent box contains both
the exhaust fan which is pulling air
from the HeliFire 360, and the air inlet
and restrictor which regulates the
proper air flow into the HeliFire 360.
For a description of how the air intake
restrictor plate works, “Combustion
Air Intake Restrictor” on page 26.
7”
12”
1 1/2” maximum facing thickness
9 5/8”
12 1/2”
7 3/8”
15”
2”
Figure 58: Flush mount power
vent dimensions.
Cut and frame a 12 5/16” by 12 5/16”
opening.
19 1/8”
20 1/4”
17 5/8”
16 1/2”
9 1/2”
1 1/2”
Maximum
Roof / Siding Material
Outlet
Blower Motor
Arrow must remain above the outlet
so that rain cannot enter the outlet
“Wiring instructions.” on page 21
Installers Information
Surface Mount Power Vent
(Vertical or horizontal termination).
(Horizontal termination only)
Figure 55: Flush mount power
vent detail.
Figure 56: Flush mount inlet restrictor plate.
Air intake
restrictor
plate
Figure 57: Flush mount
front cover.
Flush Mount Framing Note:
Flush Mount Power Vent