Installers Information
4”
Hose
clamp
4”
Flexible
venting
Self tapping
screws
Power venting - flexible venting connection
Use supplied hose clamps to secure the flexible venting to
the power venting collar. For additional security, apply at
least one self tapping screw through vacant screw slots on
the band. This will ensure that the venting never works its
way off of the collar.
4 1/2”
Engineered Stud Brackets
Stud brackets for 2x6 studs are used
to guide the flexible venting from the
fire feature venting collar to the power
venting exhaust. Use stud brackets
to maintain the structural integrity
of the studs and to keep the venting
from unnecessary movement. These
brackets can also be used to guide
the venting through a floor or ceiling.
To install, cut out a 4 5/8” section
from a stud and fasten two brackets
to each stud. The HeliFire 360 comes
with 4 pairs of brackets. Additional
brackets can be ordered.
STUD
BRACKETS
#8 X 3/4”
WOOD
SCREW
MIN. 24
PLACES
Venting through combustible ceiling or floor
Fire stops can be used to support and guide the flexible
venting material through combustible ceiling or floor
surfaces.
Consult local building codes
for specific requirements.
NOTE
4 pair of engineered stud brackts come with the surface mounted power
vent kit and the Flush mount vent kit. Use as many brackets as is necessary
to maintain a 1/4 inch clearance between the flexible vent and any combus-
tible material throughout the length of the exhaust portion of the flexible
vent. If additional stud brackets are required, packages of 4 pair can be
ordered through a Town & Country Retailer.
Figure 59: Engineered stud
brackets.
Figure 60: Engineered stud
brackets on a 2 X 6.
Figure 61: Power vent and Intake vent
connection.
28
TCHF.22bodya_ 090617-36
TCHF.22STbodya
5055.64-a