background image

tousek

  /  E_SWING-X_42001005  /  06. 02. 2012 

- 9 -

4x0,75 

mm

2

15

12A

12

3T

1

14

11

4R

1

4T

11

5

10

2

9

7

8

*)

3R

6

13

4x1,5 mm

2

2x0,75 mm

2

3x1,5 mm

2

3x1 mm

2

2x0,75 mm

2

2x1 mm

2

4x0,75 mm

2

2x0,75 mm

2

3x0,75 mm

2

15

3x0,75 mm

2

15

15

4x1,5 mm

2

 NOTE 

concerning cable laying

The 

electric 

cables 

have 

to 

be 

laid 

in 

insulating 

sleeves 

which

 

are 

suitable 

for 

underground 

usage. 

The 

insulating 

sleeves 

have to be lead into the inner of the operator housing.

230 

cables 

and 

control 

lines 

have 

to 

be 

laid 

in 

separate 

sleeves. 

Only 

double-insulated 

cables, 

which 

are 

suitable 

for 

under

-

ground usage (e.g. E-YY

-J) may be used.

In 

case 

that 

special 

regulations 

require 

another 

type 

of 

cable,

 

cables according to these regulations have to be used.

 

SAFETY

 NOTE

Please 

be 

aware 

that 

the 

beside 

picture 

is 

only 

a symbolic 

sample 

illustration 

of 

gate 

facility 

and 

may 

therefore 

not 

show 

all 

safety 

devices 

required 

for 

your 

specific

 

application. To 

achieve 

an 

optimum 

safety 

level 

at 

your 

gate 

facility

please 

make 

sure 

that 

all 

safety 

 components 

and 

acces

-

sories 

which 

- according 

to 

the 

applying 

safety 

rules 

and 

laws 

- are 

required 

in 

your 

particular 

case 

(e.g. 

photocells, 

induction 

loops, 

sensing 

edges, 

signal 

lamps, 

traffic 

lights, 

mains- 

and 

emergency 

power 

off 

switches 

etc.) 

are 

properly 

installed, operated, and serviced. All 

possible

 bruise, 

shear 

and 

general 

danger 

areas 

of 

the 

motorised gate have to be secured.  In 

this 

context 

please 

follow 

the 

EU 

Machine 

Directive, 

accident 

prevention 

rules 

and 

laws, 

as 

well 

as 

applying 

EU- 

and 

national 

standards 

in 

force 

at 

the 

time 

of 

installation 

and operation of the gate facility

.

The 

Tousek 

Ges.m.b.H. 

cannot 

be 

held 

responsible 

for 

any 

consequences 

resulting 

from 

 disregard 

of 

applying 

standards 

and 

laws 

during 

installation 

or 

operation 

of 

the 

gate facility

.

The 

0,75mm2 

control 

lines 

are 

shown

 

without 

ground

 lead. 

In 

order 

to 

facilitate 

connections 

we 

recommend 

using 

flexible 

wires 

and 

not 

using 

thicker 

wires 

for 

the 

control lines.

4.

 

Cable plan 

 

swing gate operator SWING X

1

 

operator

 T

ousek

 SWING

 X

2

 

electronic logic control

3

 

external

 fotocell

 (T

: transmitter

, R:

 receiver)

4

 

internal

 fotocell

 (T

: transmitter

, R:

 receiver)

5

 

pushbutton momentary conta

ct switch

6

 

key-operated

 momentary

 con

tact

 switch

7

 

signa

l light

8

 

radio

 remote

 receiver

, *)

 included

 into

 the

 logic

 control

 box

 on

 the

 „ST“-models)

9

 

antenna

 (connection

 to

 radio

 receiver

 with

 coaxial

 cable)

10

 main power switch and fuse 1

A

 

Note: 

An all-pole disconnectin

g main switch with a contact

 

 

open

ing-gap of minimum 3 m

m has to be foreseen

11

 safety sensing edges

12

 electric

 lock

13

 hinge

lockiing

 bar

14

 floor

 stops

15

 connection

 box

 

Important

• 

The 

motor 

and 

sensor 

wires 

have 

to 

be 

 supplied 

to 

the 

control 

unit 

by 

two

 

separate 

lines

 . 

The 

sensor 

wire 

must 

not exceed the 

max. length of 50m

 !

• 

For 

the 

sensor 

supply 

line 

between 

operator 

and 

electronic 

control

 

make 

sure 

that 

only 

the 

electronic 

control 

cables 

are 

being 

clamped 

-  

do 

not 

clamp 

ground 

wire 

(earth 

lead)

Содержание Swing-X

Страница 1: ...Installation and operating instructions Swing gate operator SWING X ...

Страница 2: ...for the Handauslöser has to be placed next to its operating element The electric motor heats up during operation Therefore the device should only be touched after it has cooled off Please make sure that no other persons are on site of the motorised gate area especially in when operating the facility in hold to run mode switch with OFF pre adjustment The pre adjusted OFF button switch has to be pla...

Страница 3: ...uching an obstacle the operator stops and reverses automatically This guarantees a high degree of safety the operator closes the gate reliably The emergency release which is important in case of power failure is lockable with a stan dard profile half cylinder It can therefore be replaced and integrated into an already existing house key system The cylinder and 3 keys are included as standard equip...

Страница 4: ...hat can be used for gates below 200kg and with a wing width below 3m for adjustment of limit positions OPEN and CLOSED Gates with a weight above 200kg and more than 3m gate width can not be used with the internal limit stops please use external limit stops 4 for gate limit positions particularly in the closed position it is recommended to use always a floor limit stop 4 or Tousek piston rod With l...

Страница 5: ...t centered inside to gate leaf A B C D INSIDE max 60mm A B C D INSIDE Mounting measures SWING X3 opening to the INSIDE SWING X3 1 standard stroke SWING X3 1LH long stroke Application standard standard for larger columns for larger opening angle A mm 145 190 180 250 160 B mm 145 190 160 200 C mm 860 990 990 990 D mm 110 130 130 130 max opening angle 100 110 100 120 max wing width 3m 3m 3m 3m Mounti...

Страница 6: ... fully closed and that the vertical misalignment V 65mm between the two welding parts is kept to ensure a levelled mounting of the operator With lean or wooden gates the welding part should not be mounted directly on the gate Please use for that a flat steel bar support the front welding part 1 with a gusset plate 3 Mounting measures opening to the OUTSIDE SWING X3 1 standard stroke SWING X4 1 sta...

Страница 7: ...ve the internal limit stop closed 5 after dismantling the hexagon head screw towards the part L on contact After that please tighten the hexagon head screw Now move the gate into OPEN limit position Now move the internal limit stop open 6 after dis mantling the hexagon head screw towards the partl L on contact After that please tighten the hexagon head screw again Lock the operator again 5 L 6 L R...

Страница 8: ...unit please see manual for control unit Warning Before carrying out the electrical connections the power supply of the gate facility must be turned off The safety regulations for electric shock prevention have to be complied The device should only be connected by qualified personnel The device should not be used in an explosive environment An all pole disconnecting mains switch with a contact open...

Страница 9: ...e have to be secured In this context please follow the EU Machine Directive accident prevention rules and laws as well as applying EU and national standards in force at the time of installation and operation of the gate facility The Tousek Ges m b H cannot be held responsible for any consequences resulting from disregard of applying standards and laws during installation or operation of the gate f...

Страница 10: ...res in mm 1 front welding part installation on the gate supported by gusset plate 2 rear welding part installation on the gate column supported by gusset plate 5 internal limit stop for position CLOSED with gates opening to the inside 6 internal limit stop for position OPEN with gates opening to the inside L running part measures and technical modifications subject to change 5 Dimensioned sketch S...

Страница 11: ...tousek E_SWING X_42001005 06 02 2012 11 ...

Страница 12: ... Tousek GmbH Germany D 83395 Freilassing Traunsteiner Straße 12 Tel 49 86 54 77 66 0 Fax 49 86 54 5 71 96 info tousek de Tousek GmbH Switzerland CH 6275 Ballwil Bahnhofstraße 14 Tel 41 0 41 448 2965 Fax 41 0 41 448 2966 info tousek ch Tousek Sp z o o Poland PL 43 190 Mikołów k Katowic Gliwicka 67 Tel 48 32 738 53 65 Fax 48 32 738 53 66 info tousek pl Tousek s r o Czech Republic CZ 130 00 Praha 3 J...

Отзывы: