1.  General  

Swing gate operator SWING-X

Characteristics

•  electromechanical swing gate operator for 230V a.c.
•  gate weight max. 500kg (per wing)
•  self-locking gear mechanism
•  high-grade bronze worm wheel
•  emergency release lockable with standard half cylinder
•  torque sensor
•  adjustable internal limit stops (mechanical)
•  adjustable soft stop
•  automatic reverse system ARS
•  suitable for  subsequent installation
•  elegant design
• 

 

General features

The swing gate operator TOUSEK SWING X, can be easily installed at new and also already existing swing gate facilities

 

For the development of the SWING X electromechanic operator the main objective was set upon reliability and long durability. 

For this reason all parts are made of premium materials such as aluminium, stainless or galvanised steel. 

Also the whole gearing which is placed in a diecast aluminium housing as well as the drive unit are entirely made of metal. This 

ensures long lasting trouble-free operation.

The drive/operator is gimbal-mounted on both gate and column side. This enables an absolutely free of play installation of the 

operator as well as smooth and even movement of the gate.

An extremely massive spindle together with a spindle socket made of brass ensures a long lasting and reliable operation.

Of course the spindle is supported on both sides. This prevents unwanted vibrations.

A torque sensor enables the use of the automatic reverse system (ARS). When touching an obstacle the operator stops and 

reverses automatically. This guarantees a high degree of safety.

the operator closes the gate reliably. The emergency release which is important in case of power failure is lockable with a stan

-

dard profile half cylinder. It can therefore be replaced and integrated into an already existing house key system. The cylinder 

and 3 keys are included as standard equipment.

The operators ensure the blocking of the gate and therefore usually do not need the use of electric locks. 

To obtain a fixed detention of the gate in the end positions it can also be useful for blocking gate operators - according to the 

installation- to install an additional locking device such as e.g. a electronic lock. 

In order to avoid a limit stop on the floor - which can be dangerous and annoying - the operator has a built-in mechanical limit 

stop.

Technical data

Swing gate operator  

SWING-

X3/1 X3/1LH X4/1 X4/1LH X5/1LH

X3/1

X3/1LH

X4/1

X4/1LH

X5/1LH

Power supply

230Va.c., 50Hz

Motor condensator

   10µF

Max. wing width

3m

4m

4,5m

5m

max. stroke

320mm    450mm

320mm   

450mm

Max. wing weight

500kg

travel speed

14mm/s

11mm/s

Operating factor  

(mode

 S3)

40%

Thrust

4000N

5000N

6500N

Ambient 

temperature

-20° bis +40°C

Article no.

11260310 11260340 11260360 11260370 11260420

Other

blocking in open and closed position • force adjustment through control unit • emergency release lockable through 

standard half cylinder • adjustable Anschläge • torque sensor

 

optional:

 boltable motor attachment brackets for gate and column (galvanised or stainless steel)   

 

Note: Max. wing widths do neither apply to full-panel gates (but to stave or trellised gates) nor to non-horizontal gates

Содержание Swing-X

Страница 1: ...Installation and operating instructions Swing gate operator SWING X ...

Страница 2: ...for the Handauslöser has to be placed next to its operating element The electric motor heats up during operation Therefore the device should only be touched after it has cooled off Please make sure that no other persons are on site of the motorised gate area especially in when operating the facility in hold to run mode switch with OFF pre adjustment The pre adjusted OFF button switch has to be pla...

Страница 3: ...uching an obstacle the operator stops and reverses automatically This guarantees a high degree of safety the operator closes the gate reliably The emergency release which is important in case of power failure is lockable with a stan dard profile half cylinder It can therefore be replaced and integrated into an already existing house key system The cylinder and 3 keys are included as standard equip...

Страница 4: ...hat can be used for gates below 200kg and with a wing width below 3m for adjustment of limit positions OPEN and CLOSED Gates with a weight above 200kg and more than 3m gate width can not be used with the internal limit stops please use external limit stops 4 for gate limit positions particularly in the closed position it is recommended to use always a floor limit stop 4 or Tousek piston rod With l...

Страница 5: ...t centered inside to gate leaf A B C D INSIDE max 60mm A B C D INSIDE Mounting measures SWING X3 opening to the INSIDE SWING X3 1 standard stroke SWING X3 1LH long stroke Application standard standard for larger columns for larger opening angle A mm 145 190 180 250 160 B mm 145 190 160 200 C mm 860 990 990 990 D mm 110 130 130 130 max opening angle 100 110 100 120 max wing width 3m 3m 3m 3m Mounti...

Страница 6: ... fully closed and that the vertical misalignment V 65mm between the two welding parts is kept to ensure a levelled mounting of the operator With lean or wooden gates the welding part should not be mounted directly on the gate Please use for that a flat steel bar support the front welding part 1 with a gusset plate 3 Mounting measures opening to the OUTSIDE SWING X3 1 standard stroke SWING X4 1 sta...

Страница 7: ...ve the internal limit stop closed 5 after dismantling the hexagon head screw towards the part L on contact After that please tighten the hexagon head screw Now move the gate into OPEN limit position Now move the internal limit stop open 6 after dis mantling the hexagon head screw towards the partl L on contact After that please tighten the hexagon head screw again Lock the operator again 5 L 6 L R...

Страница 8: ...unit please see manual for control unit Warning Before carrying out the electrical connections the power supply of the gate facility must be turned off The safety regulations for electric shock prevention have to be complied The device should only be connected by qualified personnel The device should not be used in an explosive environment An all pole disconnecting mains switch with a contact open...

Страница 9: ...e have to be secured In this context please follow the EU Machine Directive accident prevention rules and laws as well as applying EU and national standards in force at the time of installation and operation of the gate facility The Tousek Ges m b H cannot be held responsible for any consequences resulting from disregard of applying standards and laws during installation or operation of the gate f...

Страница 10: ...res in mm 1 front welding part installation on the gate supported by gusset plate 2 rear welding part installation on the gate column supported by gusset plate 5 internal limit stop for position CLOSED with gates opening to the inside 6 internal limit stop for position OPEN with gates opening to the inside L running part measures and technical modifications subject to change 5 Dimensioned sketch S...

Страница 11: ...tousek E_SWING X_42001005 06 02 2012 11 ...

Страница 12: ... Tousek GmbH Germany D 83395 Freilassing Traunsteiner Straße 12 Tel 49 86 54 77 66 0 Fax 49 86 54 5 71 96 info tousek de Tousek GmbH Switzerland CH 6275 Ballwil Bahnhofstraße 14 Tel 41 0 41 448 2965 Fax 41 0 41 448 2966 info tousek ch Tousek Sp z o o Poland PL 43 190 Mikołów k Katowic Gliwicka 67 Tel 48 32 738 53 65 Fax 48 32 738 53 66 info tousek pl Tousek s r o Czech Republic CZ 130 00 Praha 3 J...