tousek
/ E_SWING-X_42001005 / 06. 02. 2012
- 7 -
2b. Installation of the operator
Installation
• After having mounted the welding parts
and junction plates(3)
please install the operator as follows.
• Before mounting please note that the moving parts
should be lubricated on their pivotal points!
• Now slide the operator with the fork on the rear welding
part
(2)
, insert the brazed screw from above, place a plate
below and fix with by using the screw nut.
• the screw nut that has been tigthened before, should
now be opened a little (approx. 1/4 turn), to ensure the
movability on the pivotal point!
• Now turn the gate wing until the bolt/pin of the part
(L)
(=
part which is moved through the operator spindle) can be
put from above into the drilling of the front welding part
(1).
Then place a plate below and fix by using the screw nut.
• the screw nut that has been tigthened just now, should
now be opened a little (approx. 1/4 turn), to ensure the
movability on the pivotal point!
Lubrication
for moving mounting parts
• The pivotal points of the operators (holes of welding
parts and corresponding pins/screws, that are used
for the attachment of the operator on the welding
parts, have to be lubricated before installation
of
the operator !
1
3
2
3
• Now move the internal limit stop „closed“
(5)-
after
dismantling the hexagon head screw- towards the part
(L)
(on contact!). After that please
tighten
the hexagon head
screw.
• Now move the gate into OPEN limit position.
• Now move the internal limit stop „open“
(6)
-after dis-
mantling the hexagon head screw - towards the partl
(L)
(on contact!). After that please
tighten
the hexagon head
screw again.
• Lock the operator again.
5
L
6
L
Readjustment
• When operator is ready for operation , place/drive/move
the operator with electricity (through an impulse) into
limit positions and if necessary readjust the internal limit
stops.
• Before adjusting the operator please
disconnect from power supply
2c. Adjustment of internal limit stops
Installation
• The operator type SWING X is equipped with internal limit
stops that can be used for gates
below 200kg
and with a
wing width below 3m for adjustment of limit positions OPEN
and CLOSED.
• The following steps describe the adjustment for
gates ope-
ning to the inside
(when opening to the outside then the
limit stops have exactly the contrary function -
(6)
for closed
and
(5)
for open position):
• Unlock the gate
(see „emergency release“).
• Manually move the gate with unlocked operator into end position
CLOSED.
Important
(for gate wing > 200kg or >3m)
• Gates with a weight over 200kg or with a width abo
-
ve 3m, as described here, can not be used with the
internal limit stops, please use external limit stops
(4) for gate limit positions!