- 34 -
tousek
/ EN_REX-Force_01 / 25. 03. 2020
optional module Courtyard lamp/Control lamp or Gate status display
•
Turn off power supply before plugging in the
additional module!
• Depending on which device, e.g. a
courtyard-/Control lamp
is chosen or
evaluation of gate status
should be effected, the corresponding module
(Z)
has to be plugged to the according slot/plug
(ZM)
of control board.
• Additionally the corresponding value has to be selected in menu point „Additional
module“.
Additional module
Courtyard lamp/
Control lamp
• On the terminals 12/13
a Courtyard lamp
(H)
can be connected:
230V, max. 100W
• On the terminals 70/71
a control lamp
(K)
can be connected:
24Vd.c., max. 2W
12 13 70 71
L N
H
K
– +
Additional module
Gate status display
• with potential free signal contacts K1 (Kl.
90/91) and K2 (Kl. 92/93) the gate staturs
can be evaluated in two ways (see menu
point „Additional module“).
• Contact load:
24Va.c./d.c., max. 10W
Function
K1 K2
Gate status display
1
Gate in CLOSE-Position
1
0
Gate in OPEN-Position
0
1
2
Gate in CLOSE-Position
0
0
Gate opens or closes
0
1
Gate stopped or fault
(Gate not in end position)
1
0
Gate in OPEN-position
1
1
signal contact: 0 = open, 1= closed
90 91 92 93
signal contact
K1
K2
Z
ZM
ST REX
ZM