Function
K1
K2
Gate status display
1
Gate in CLOSE-Position
1
0
Gate in OPEN-Position
0
1
2
Gate in CLOSE-Position
0
0
Gate opens or closes
0
1
Gate stopped or fault
(Gate not in end position)
1
0
Gate in OPEN-position
1
1
0 = signal contact open, 1= signal contact closed
Only if an additional module is installed you can carry out one of these adjustments (courtyard-/control
hence gate status 1 or 2).
Peripherals
Connections and adjustments
traffic light
Peripherals
not active
active:
Traffic light function active
•
With the optional traffic light control unit, that has to be connected to the bus terminals (B):
term. Z1: 88, 89
(
page 41)
, you can implement a traffic light operation mode.
•
Note: The functions and settings relevant for the traffic light operation are displayed in the menu only
after selecting “active” →
see
•
Connection of the traffic light
→
see instruction manual of the traffic light control unit.
Valid for the traffic light mode:
• The inputs of the pulse buttons of the drive control have no function and the impulse emis-
sion is only possible via traffic light board!
• When using a radio receiver and the traffic light mode, the receiver is not to be plugged
into the slot of the control unit, but into the slot of the traffic light control!
page 45
locking
Peripherals
magnetic clamp:
locking with optional magnetic clamp module.
electric drop:
locking with additional electric drop module.
reverse stroke
(only with activated electric drop)
Peripherals
not active
0,5–8s adjustable:
If the function is activated, a short closing movement is first initiated after an impulse with the but
-
ton or the radio remote control is given. Then the electric drop switches and the gate opens (serves to relax the latch
before unlocking). If the electric drop function is not activated, the reversal stroke will not be executed.
delay magnetic clamp
Peripherals
OFF
0,1–1s adjustable:
Time for releasing the magnetic clamp before the gate movement.
electric drop
Peripherals
OPEN and CLOSE:
locking with an electric drop in both end positions of the gate.
OPEN only:
locking with an electric drop only in the gate open position.
CLOSE only:
locking with an electric drop only in the gate closed position.
additional module
Peripherals
court. / control lamp:
Fades in the menu points „courtyard lamp“ and „control lamp“ for adjustment (if not selected, these
menu points will not be shown on the display).
gate status display 1:
with the two potential-free signal
contacts K1 and K2, the gate end positions (limits) can be
evaluated.
gate status display 2:
with the two potential-free signal
contacts K1 and K2, the gate end positions (limits), the
gate movement as well as a gate stop outside of the end
positions can be evaluated: