- 22 -
tousek
/ EN_REX-Force_01 / 25. 03. 2020
2.7
Connections and adjustments
REX Force
As impulse-, pedestrian-, close- and impulse-OPEN buttons pushbuttons or key switches as well as external ra-
dio receivers with potential free make contacts can be used.
As stop switch a break contact has to be used!
In traffic light mode the impulse-, pedestrian-, close- and impulse-OPEN buttons are without any
function
.
Buttons / switches
Connections and adjustments
Warning
•
Before taking off the control cover, the
mains switch must be turned off!
•
If the control is power supplied, its inner part is under
tension.
•
In order to avoid electrical strokes, the safety regula-
tions have to be kept.
•
The device may only be connected by trained profes-
sionals.
•
The product is not suitable for installation in explosion-
hazardous areas.
•
An all-pole disconnecting mains switch with a contact
opening gap of min. 3 mm has to be foreseen. The
gate facility has to be secured according to the valid
safety regulations!
•
IMPORTANT: The control lines (sensor, buttons, radio,
photocells, etc.) have to be laid separately from the
230V lines (supply line, motors, signal lamp).
• A general status display of all inputs can be found in the menu DIAGNOSIS / STATUS DISPLAY
The different menu points are indicated as follows:
= selectable setting
= factory settings
= status display
G
shows the menu points which are in the “ BASIC SETTINGS”
impulse button
(NO contact,terminals Z1: 30/32)
Buttons/switches
OPEN/ STOP / CLOSE
(factory setting): After giving a
command via impulse switch the motor starts an opening
or closing movement. If the impulse switch is pressed
again during this movement, the motor stops. With the
next command, the motor drives in the opposite direction
of the last gate movement.
OPEN / CLOSE / OPEN impulse repetition:
After giv-
ing a command via impulse switch the motor starts an
opening or closing movement. If the impulse switch gets
pressed again during this movement, the motor reverses
OPEN:
It is only possible to give an opening command by using the impulse switch. Closing the gate with the impulse
switch is not possible.
DEAD-MAN:
The motor opens as long as the impulse switch is pressed – closing the gate with the impulse switch is
not possible. As soon as the switch is released, the gate stops. If hold to run operating mode is selected,
the radio
receiver slot (FE) is set out of order for reasons of safety.
IMPORTANT: Do not start the commissioning process in dead man mode.
If desired, select this mode only after commissioning.
•
In this operation mode it is not possible to stop the motor with the impulse switch – it always
travels until reaching an end position. (Opened or closed position).
• for the function OPEN/CLOSE/OPEN we strongly suggest the installation of a photocell!
Impulse switch
(e.g key switch EPZ 1-2T)
2 P 1
32
30
Z1