tousek
/ EN_REX-Force_01 / 25. 03. 2020
- 35 -
The mechanical stops have to be placed so
that possibly existing safety contact edges
can not be triggered, as this would lead to
an error message.
Note: The factory settings of the
single menu points are marked
with
in this manual.
status display
Diagnosis
Status display
for inputs as photocell, safety sensing edges, stop button, impulse switch ....
I
impulse button
P
pedestrian entry
C
CLOSE-button
S
STOP-button
O
OPEN-button
L
induction loop
Pi
inner photocell
Po
outer photocell
Pb
back area photocell
Status: not triggered
Status: triggered
Status: deactivated in menu
$
o
$
$
-
delete position
Diagnosis
NO:
does not delete the end positions “gate closed”
and “gate open”
YES:
the determined end positions are beeing deleted.
Note: the end positions will be determined after new impulse.
factory setting
Diagnosis
NO:
no reset back to factory settings
YES:
reset back to factory settings
software version
Diagnosis
shows the software version on display
serial number
Diagnosis
shows the serial number on display
protocol
Diagnosis
shows the protocol list on display:
all events that take place are protocolled in this list.
with the buttons
+
and
-
the single events can be seen:
status Sensor
Diagnosis
shows the sensordata
All inputs okay.
Inner photocell is triggered.
Photocell back area is deactivated in the menu.
All other inputs are ok.
e.g.
Diagnosis
Connections and adjustments
$$$$$$$$$$$$$$$$
$$$$$$$$$$$$$$$$
T -00 00:00:00.0
event
With
*
the protocol beginning
hence the end is shown
Type of event
Time since the last event:
DAYS HOURS : MINUTES : SECONDS
$$$$$$$$$$$$$$$$
$$$$$$$$$$$$$$$$
IPCSOL Pi Po Pb
$$$$$$$$$$$$$$$$
$$$$$$$$$$$$$$$$
IPCSOL Pi Po Pb