PIREG 545 cUL Operators Guide 2021
31
Settings Menu 103 – Start De-
lay
SETTINGS 103
Start delay: 8.8s
(0.0...9.9s)
Setting menu 103 is used to program a time delay that will proceed
the Sealing time. Press the
buttons to alter setting and accept
by pressing the Enter button
≡
. The Start delay begins when the
start signal is received and is then followed by the Sealing time. The
start delay can be programmed between 0.0 and 9.9 seconds.
Press the Menu Scroll
to advance to Settings menu 104
Settings Menu 104 – Sealing
Time
SETTINGS 104
Sealing time: 88.8s
(Extern/0.0...99.9s)
Setting menu 104 is used to program the Sealing time. Press the
buttons to alter setting and accept by pressing the Enter button
≡
.
The Sealing time can be programmed between 0.0 and 99.9 sec-
onds or can be programmed by an external timer.
Note
: This function is only active when Time Control is set to ON in
Configuration menu 209
Press the Menu Scroll
to advance to Settings menu 105
Settings Menu 105 – Cooling
Mode
SETTINGS 105
Cooling temp.: 100
°C
(20...300
°C)
Setting menu 105 is used to program the cooling mode. Press the
buttons to alter setting and accept by pressing the Enter button
≡
.
Note:
The Cooling mode can be programmed to operate in one of
the following modes programmable in Configuration menu 210.
- Absolute (temperature): Range 20…300°C. It is limited to the
selected maximum temperature setting programmed in Config-
uration menu 206 and the minimum value is 20°C.
- Relative (percentage of Sealing temp.): Range 20…100%.
- Time: Range 0…99.9s
Press the Menu Scroll
to advance to Settings menu 106
Settings Menu 106 – Hold
Mode
SETTINGS 106
Hold mode: OFF
(OFF/ON/2 sec.)
Settings menu 106, Hold mode, allows the operator to display the
final sealing temperature achieved during the sealing cycle. This
temperature reading will be displayed in the upper right-hand corner
of the Home Screen (“Act” temperature). Press the
buttons to
alter setting and accept by pressing the Enter button
≡
.
Note:
The Hold mode can be programmed to operate in one of the
following modes:
- Off: Actual temperature will be displayed continuously.
- On: The final seal temperature achieved will be displayed until
the start of the next sealing cycle.
- 2 Sec.: The final seal temperature achieved will be display for
two seconds following the sealing cycle.
Press the Menu Scroll
to advance to Settings menu 107
Settings Menu 107 - AutoCal
SETTINGS 107
AUTOCAL to: 20
°C
(0...50
°C)
Start with Enter
Settings menu 107, AUTOCAL, calibrates the voltage and current
signals to the reference ambient temperature displayed on this menu
screen. The reference temperature should be the actual temperature
of the ambient TOSS Alloy 20 heat seal band, within the range of 0
- 50°C. Press the
buttons to alter the reference temperature
setting and accept by pressing the Enter button
≡
. Pressing the En-
ter button a second time begins the execution of AUTOCAL. Upon
completion, the reference temp will appear on the Home Screen,
“Act” temperature.