PIREG 545 cUL Operators Guide 2021
29
Home Screen w/ time control ON -
Continued
Line 1
Set=888
°C
/
//
Act=888
°C
Line 2
_________
Line 3
Sealing time:88.8s
x
x
Line 4
Cooling temp.: 888°C
Π
Line 5
Batch Count: 8888888
Line 3 (Continued)
On the right side the symbol “
x
x
“ is dis-
played when the activation of locking was performed by press-
ing the button combination
+
+
≡
simultaneously. Before
using this feature, it must be activated in Advance Configuration
menu 313.
Line 4:
Display of the programmed cooling phase set in Setting
menu 105. Cooling phase can be programmed as “temp.” or
“time” in Configuration menu 210. During a sealing cycle the
cooling time display, when selected, can be programmed in the
Advance Config menu 309 to count down or up to show the
sequence of cooling time or it can be programmed to remain
fixed.
On the right side the symbol “1“ or “2“ display the selected cal-
ibration 1 or 2, if the calibration switching is activated. If the
measurement pause is activated, the symbol Π is shown on the
right side.
Symbol
:
The Symbol “
” in line 3 and 4 marks the activation
of sealing and cooling phase.
Line 5
: Displays Batch counting. This is only if the batch coun-
ter is ON in Configuration menu 226. The batch counter will be
reset in Setting menu 113.
Function of Buttons form the Home Screen
Button
: Advance to the setting menus, starting with Settings
menu 101.
Button
>2s: Hold the button
for longer than 2s to advance
to the Configuration menus, start with the menu 201.
Button
+
>2s: If the advanced PIREG
®
features is acti-
vated in Configuration menu 227, hold the button
and
for
longer than 2s to advance to the Advanced Configuration
menus, start menu 301.
Button
+
>2s: If the advanced PIREG
®
features is acti-
vated in Configuration menu 227, hold the button
and
for
longer than 2s to advance to the Security Protection menus,
start with the menu 401.
Button
≡
: When the “HAND” function is activated in Configura-
tion menu 213, pressing Hand button
≡
can trigger a manual
sealing cycle, as long as
≡
button is kept pressed or the current
programmed cycle.
Button
: Setting of brightness of display-lighting. The set-
ting will be automatic take-over, when the setting is not altered
for 3 seconds.
6.2.2. Home Screen with time control OFF
Home Screen w/ time control OFF
Line 1
Set= 888°C
/
Act=888°C
Line 2
_________
Line 3
X
Line 4
1
Line 5
Batch Count: 8888888
Line 1…2:
Functions same as described above.
Line 3
: On the right side the symbol “
X
“ is displayed when the
activation of locking was performed by pressing the scroll but-
ton
at turn ON.
On the right side the symbol “
x
x
“ is displayed when the activation
of locking was performed by pressing the button combination
+
+
≡
simultaneously. Before using this feature, it has to be
activated in Advance Configuration menu 313.
Line 4
: On the right side the symbol “1“ or “2“ display the se-
lected calibration 1 or 2, if the calibration switching is acti-
vated. If the measurement pause is activated, on the right side
the symbol Π is showed.
Line 5: