PIREG 545 cUL Operators Guide 2021
27
5.10.1. Timing Charts Continued:
Relays K1, K2, and Output 1 are activated when "Act" temperature is within the temperature OK zone of
the "Set" temperature. The OK zone is set in the setting menu 207 and 208. (Chart #8).
Relays K1, K2 and Output 1 are activated when the "Act' Temperature is within the temperature OK zone
based on the "Set" temperature. If the "Act" temperature leaves the OK zone, the relays/output will deacti-
vate and remain so even when "Act" temperature returns to the OK zone (w/ Latch function). The OK
zone is set in the setting menu 207 and 208. (Chart #9)
5.11. Display functions
5.11.1. Languages
:
The following languages can be set for the PIREG
®
-545 display unit:
German
English
French
Italian
Spanish
Russian
5.11.2. Brightness
:
Setting the brightness of the display-lighting can be altered by pressing the
buttons while in the Home
Screen. The setting will be saved when the setting has not been altered for 3 seconds.
5.11.3. Hold mode
:
If the “Hold” mode is enabled, the actual temperature value “ACT” which was measured at the end of the
sealing process or the sealing time will be displayed. You can select whether the measured actual value is
only displayed for 2 seconds or until the following sealing process or sealing cycle is started.
5.11.4. Batch and Cycle Counters
:
The PIREG
®
-545 has two resettable batch counters (0-9999999) for counting the number of seal cycles for
a given batch. One can be programmed so as to be displayed on the Home Screen and it can be reset
from the Settings Menu 113. The second can be both found and reset from the Configuration menu 214.
In the case of an overflow the counters automatically reset to zero.
The PIREG
®
-545’s also has a total life-cycle counter (0-999999999) that cannot be reset.
5.11.5. Recipe Storage
:
The PIREG
®
-545 can store up to 9 recipe settings. These recipes store the parameter settings for various
applications making it easy for the operator to quickly recall a stored recipe when the sealing application
has changed.
5.11.6. Security Protection
:
The PIREG
®
545 controller offers three levels of Security Protection designed to allow the user to limit
access to the various menu settings. (See
Section 7.1.
) The three levels including the menu screens they
protect are as follows:
ON
active when
ACT=SET wL
OFF
+Δ Set
Temperature
Set Temperature
-Δ Set
Temperature
ON
active when
ACT=SET
OFF
8
9
cycle time