PIREG 545 cUL Operators Guide 2021 

39

 

Configuration Menu 226 – 
Batch Counter-Home Screen 

 

 

 

 

  CONFIGURATION  226 

 

Batch counter:   OFF 

 

                     

 

(OFF/ON)             

 

 

 

 
Selection of batch counter turned on or off. The batch counter dis-
plays the executed sealing cycles in the Home Screen. The batch 
counter will be reset in setting menu 113 

 

Configuration Menu 227 – 
Advance PIREG Features 

 

 

 

 

  CONFIGURATION  227 

 

Adv. PIREG features: 

 

 OFF                 

 

(OFF/ON)             

 

 

 

 
Selection for deactivating and activating advanced PIREG

®

 features. 

 

 
 
  

6.5. Advanced configuration menu 

 

 

Advancing to the Advanced Configuration menus:

 From the Home Screen, simultaneously hold the 

Menu Scroll button 

 and 

 button for longer than 2s to change to the Advanced Configuration menus. 

Then press the Menu Scroll 

 button to advance through the various Advanced Configuration menus. 

 
 

 

Advance Config. Menu 301 – 
Tc Correction  

 

 

 

 

ADVANCE CONFIG.  301 

 

Tc corr.: OFF        

 

                     

 

(OFF/Single pt/8 pt) 

 

 

 

 
Press the 

 button to change to the next advance config. menu  

-with Tc correction “off” change to advance config. menu 304. 
-with Tc correction “Single pt” change to advance config. menu 302. 
-wit Tc correction “8 pt” change to advance config. menu 302a. 

Line 1:

 Name and Number of menu 

Line 2:

 Selection for deactivating and activating the temperature co-

efficient  correction.  The  selection  is  confirmed  as  always  with  the 
button 

Line 3:

 In line 3 will be displayed the text “saved”, if the temperature 

coefficient correction was successfully running after calibration. 
 

 

Advance Config. Menu 302a – 
Single Point Correction Reset  

 

 

 

 

ADVANCE CONFIG. 302a 

 

Tc correction: 

 

 Single point        

 

Reset with ENTER     

 

 

 

 

:

 Single point temperature coefficient correction chosen from menu 

301. 

Line  4:

  Direction  to  Reset.  Reset  Single  point  temperature  coeffi-

cient correction by pressing of 

 button. 

After Reset the single point temperature coefficient correction a new 
correction is possibly after a new auto-calibration. 
 

 

Advance Config. Menu 302b 
– 8-Point Correction Reset  

 

 

 

 

ADVANCE CONFIG. 302b 

 

Tc correction: 

 

 8 point             

 

Reset with ENTER     

 

 

 

 
8-point temperature coefficient correction chosen from screen 301. 

Line 4:

 Direction to Reset. Reset 8-point temperature coefficient cor-

rection by pressing of 

 button. 

After Reset the 8-point temperature coefficient correction a new cor-
rection is possibly after a new auto-calibration. 
 

Содержание PIREG 545

Страница 1: ...PIREG 545 cUL Operators Guide 2021 1 PIREG 545 Operator s Guide 539 South Main Street Phone 610 759 8883 E Mail info tossheatseal com Nazareth PA 18064 Fax 610 759 1766 Web www tossheatseal com...

Страница 2: ...5 12 3 5 EXTERNAL SOLID STATE RELAY BOOSTER 13 3 6 CONTROL INPUTS 13 3 7 CONNECTING TO THE MAINS VOLTAGE 13 3 8 THE TOSS ALLOY 20 SUITABLE HEAT SEAL BAND MATERIALS 13 3 9 BURNING IN THE GENUINE TOSS A...

Страница 3: ...6 Security Protection 27 5 11 7 Temperature unit 28 6 MENU STRUCTURE 28 6 1 START 28 6 2 HOME SCREEN 28 6 2 1 Home Screen with time control ON 28 6 2 2 Home Screen with time control OFF 29 6 2 3 Alarm...

Страница 4: ...Menu 310 Heating Ramp Up 41 Advance Config Menu 311 Transformer Type Selection 41 Advance Config Menu 312 Menu Return to Home Screen 41 Advance Config Menu 313 Locking Function ON OFF 41 Advance Conf...

Страница 5: ...8 1 SCREEN SYMBOLS 50 8 2 CONTROLLER 50 8 1 1 Standards CE marking 53 8 3 CURRENT TRANSFORMER 53 8 4 SEALING TRANSFORMER 53 8 5 EXTERNAL THERMOMETER DTM3000 53 8 6 ORDERING CODES 54 8 7 SPARE PARTS 5...

Страница 6: ...tion of the equipment The equipment can be operated without impairing the operational reliability if the conditions stated in the technical specifications are observed The equipment may only be instal...

Страница 7: ...ambient temperature 1 7 Current Transformer The current transformer is an essential part of the control system Only the Toss CT 50 current transformers may be used The current transformer may only be...

Страница 8: ...agnetic compatibility Directive EN 61000 6 2 2016 05 Electromagnetic compatibility EMC Part 6 2 Generic standards Immunity for industrial environ ments EN 61000 6 3 2011 09 Electromagnetic compatibili...

Страница 9: ...d directly from the heat seal band and are made available to the controller at rate of 50 times per second when operated at 50Hz or at a rate of 60 times a second when operated at 60Hz The PIREG 545 t...

Страница 10: ...PIREG 545 cUL Operators Guide 2021 10 2 1 Installation Overview 2 2 PIREG 545 rear electrical pin out...

Страница 11: ...PIREG 545 cUL Operators Guide 2021 11 2 3 Wiring diagram for the PIREG 545 2 4 Wiring diagram for the PIREG 545 WITH external solid state relay Booster...

Страница 12: ...issible range an Error signal will be displayed on the screen If the secondary current falls below 20A the secondary voltage wire must be looped through the CT 50 current transformer a second time or...

Страница 13: ...validated temperature is required Adjusting the vari able ppm allows the operator to calibrate the bands temperature to an independent NIST calibrated tem perature measuring device During initial hea...

Страница 14: ...guration menus Advanced Configuration menus From the Home Screen simultaneously hold the Menu Scroll button and button for longer than 2s to change to the Advanced Configuration menus Then press the M...

Страница 15: ...four selectable temperature coefficients Alloy A20C Alloy A20K Alloy L and Norex A Variable temperature coefficient exists allowing for the precise calibration of a specific heat sealing system 5 1 2...

Страница 16: ...ture has ex ceeded 95 of the desired temperature The chosen relay is released when the heat seal band s actual temperature is reported back to the PIREG 545 from V1 00 1 07 1 29 1 23 5 3 Off state In...

Страница 17: ...et temperature 5 6 Monitoring 5 6 1 Temperature diagnostic Temperature diagnostic is a temperature monitoring feature enabled and set in the PIREG 545 During the sealing process the actual temperature...

Страница 18: ...and voltage signal Ur too high 107 Temperature step down 2 66 Loose Contact 4 5 or 6 108 Temperature step up 111 Calibration Error Current signal Ir too low 6 66 10 8 Calibration Error Current signal...

Страница 19: ...Communication control TM6 thermometer 222 Communication control internal connection 1 Communication control internal connection 2 302 Temperature too low 6 33 10 Run Autocal or Loose Contact 4 5 or 6...

Страница 20: ...3 Ur signal missing Ur measuring wire loose or disconnected 4 Resistance shift partial short circuit Heat Seal band intermittently in contact with conductive parts clamp opposite heat sealing bar etc...

Страница 21: ...t start delay sealing time and cooling time will be started automatically after the Start signal is applied If the 8 point temperature coefficient correction is selected during auto calibration the co...

Страница 22: ...Fault states the PIREG 545 switches to the auto calibration state Here the PIRGEG 545 ambient temperature reading is adapted to the combination of the heat seal band and sealing transformer During th...

Страница 23: ...onds to 500 C if the selected temperature range is 500 C With Potentiometer The temperature set value is set by a potentiometer In the case of the po tentiometer the cutter is linked to the set value...

Страница 24: ...osed normal or open inverse when the relay is actuated The factory setting of this relay contact is closed normal when a fault occurs 5 9 3 Booster output The booster output 1 2 is used to control an...

Страница 25: ...ting phase Relays Output activated during cooling phase Relays Output are activated at the start of a sealing cycle or during the sealing time for the selected duration The selected duration of the im...

Страница 26: ...ling set temp achieved Seal Time Cooling Phase Start Signal Set Point Temperature ON generates cool phase impulse OFF ON switches with start signal OFF ON switches at set temp achieved OFF ON active w...

Страница 27: ...the sealing time will be displayed You can select whether the measured actual value is only displayed for 2 seconds or until the following sealing process or sealing cycle is started 5 11 4 Batch and...

Страница 28: ...internally with the C system This means that when temperatures are set in the F system display increments of 2 F may occur due to calculation rounding 6 Menu structure Shortcuts S Settings Password p...

Страница 29: ...an 2s to advance to the Configuration menus start with the menu 201 Button 2s If the advanced PIREG features is acti vated in Configuration menu 227 hold the button and for longer than 2s to advance t...

Страница 30: ...ng temperature Set value visible on Home Screen Press the buttons to alter set ting and accept by pressing the Enter button Note Sealing temperature is limited to the selected temperature range progra...

Страница 31: ...programmed in Config uration menu 206 and the minimum value is 20 C Relative percentage of Sealing temp Range 20 100 Time Range 0 99 9s Press the Menu Scroll to advance to Settings menu 106 Settings...

Страница 32: ...orrection set to 8 Point Along with reset command in Adv Config 301 302b advances to Settings menu 110 Settings Menu 109 Single Point Calibration SETTINGS 109 Sing pt calibration Set 888 C Act 888 C S...

Страница 33: ...de of the step number the symbol is shown during heat up and the symbol is shown when the temperature has been corrected Throughout the process of 8 Point temperature coefficient correc tion while the...

Страница 34: ...e ceived from the TOSS factory Save customer settings Allows machine builder to save all con figuration settings custom to the specific OEM equipment Recall customer settings Restores saved OEM equipm...

Страница 35: ...9999ppm Press the Menu Scroll to advance to Configuration menu 204d For each variable Tc setting the PIREG 545 controller determines the maximum temperature for steady S and dynamic D resistance devel...

Страница 36: ...deactivating with OFF Press Menu Scroll to change to Configuration menu with time control turned Off advance to Configuration menu 212 time control turned On advance to Configuration menu 210 Configu...

Страница 37: ...214 Seal Cycles Resettable CONFIGURATION 214 Cycles 8888888 Reset with ENTER Display of executed sealing cycles Button Press the button to set the cycles counter to zero Configuration Menu 215 Alarm R...

Страница 38: ...for setting of possible preheating time during which actual measured temperature value must be within tempera ture OK zone Configuration Menu 222 Output 1 Function CONFIGURATION 222 Output 1 OFF Selec...

Страница 39: ...change to advance config menu 302 wit Tc correction 8 pt change to advance config menu 302a Line 1 Name and Number of menu Line 2 Selection for deactivating and activating the temperature co efficien...

Страница 40: ...me 15s 15s 30s Selection for calibration compare time Advance Config Menu 307 K2 Relay Function ADVANCE CONFIG 307 Relay K2 OFF Selection function of Relay K2 For complete list of options refer to Sec...

Страница 41: ...ection for transformer type Advance Config Menu 312 Menu Return to Home Screen ADVANCE CONFIG 312 Menu return OFF OFF 20s Selection for deactivating and activating of automatic menu reset af ter 20s A...

Страница 42: ...as always with the button 1 Reset With a signal at the input the PIREG 545 executes a re set 2 Measurement pause With a high signal at the Reset input 26 in the Off state the PIREG 545 stops the resis...

Страница 43: ...easure ment making it possible to interrupt the heat seal band circuit without generating an alarm If the measurement pause is activated the symbol is shown on the right side of the cooling line on th...

Страница 44: ...rd 0000 and establish a new password The four zeros 0000 will be displayed as the password in all screens until a new password has been created Once a new password has been created four stars will rep...

Страница 45: ...okes below en ter and accept the password 1 Press the or button to enter the first digit press the Menu scroll button 2 Press the or button to enter the second digit press the Menu scroll button 3 Pre...

Страница 46: ...nction SECURITY PROTEC 406 Enter new settings password PASSWORD 0000 In Security Protection menu 406 the new password is to be entered The new password is set per digit To enter the new password begin...

Страница 47: ...w password has been entered then will be displayed The password is set per digit To enter the password begin by pressing either the or button Four zeros 0000 will appear flashing with the first digit...

Страница 48: ...Level 2 password LOCK LOCK UNLOCK CHANGE Security Protection menu 412 is the home screen for the Level 2 pass word protection Press the buttons to select the desired command and accept by pressing the...

Страница 49: ...to change the Level 2 password from an existing password to a new password In Security Protection menu 415 the current password is entered The start value from the factory is 0000 This 0000 will be di...

Страница 50: ...120 240 V Remarks to voltage value above Outer conductor neutral conductor Outer conductor outer con ductor Standard 220 15 240 V 10 Voltage fluctuation 187 264 VAC Allowable mains supply sys Three ph...

Страница 51: ...ature coeffi 3 Tk1 48 3x10 4 1 K TK2 6 12x10 6 1 K Tk3 2 80x10 9 1 K NOREX Temperature coeffi 4 Tk1 8 62x10 4 1 K Tk2 0 Tk3 0 Alloy A20K Temperature coefficient variable setting Tk1 4 00 99 99x10 4 1...

Страница 52: ...ad 2000 VA 192 W Max switching voltage 150 VDC 250 VAC Max switching current 10 A Nominal load ohmic load 8 A 250 VAC 8A 24 VDC Lifetime electrical 100x103 with ohmic load mechanical 20x106 Alarm outp...

Страница 53: ...d resistor 5 Transformation ratio 1 1000 Connections Plug in screw terminals Clamping range 0 2 2 5 mm AWG 24 12 tightening torque 0 6 0 6 Nm Material polyamide not reinforced flammability class UL94...

Страница 54: ...ication instructions are available for the PIREG 545 controller which simplify operation of the PIREG 545 Temperature coefficient correction Operation of the temperature coefficient correction which i...

Отзывы: